Модели
: PRE E 0720 HF; PRE E 0925 HF; PRE E 1129 HF.
Regulator
position
Power
7 fins
9 fins
11 fins
Fan
0
0
0
0
400
I
600
800
1000
II
900
1200
1500
I+II
1500
2000
2500
•
If you want to keep the constant temperature, please rotate the thermostat controller anti-clockwise until
the indicator go out. From this moment, the radiator will continue to work automatically keeping the
constant temperature using efficiently the electric power.
•
If you want to change the temperature please rotate the thermostat controller clockwise – to make the
temperature go up, anti-clockwise – to make the temperature go down.
•
If you want to turn off the radiator, please switch all controllers to OFF position.
VII.
Cleaning and storage
•
Before cleaning, be sure the radiator is unplugged, and it has cooled completely.
•
Do not use abrasive soaps, cleansers, or scouring pads on any part of the radiator.
•
Wipe the exterior of the radiator with a dry cloth or sponge.
•
In case of damage of the appliance, please contact our authorized service agents.
•
The storage of the appliance should be arranged in original gift box.
•
The power cable should be kept in the special section of the radiator.
•
In case of damage of the appliance, please contact our authorized service agents.
VIII.
Technical information
Models
The number
of fins
Power supply (V),
Frequency (Hz)
Power
(W)
PRE E 0715 H
7
220V ~ 50 Hz
1500 W
PRE E 0920 H
9
220V ~ 50 Hz
2000 W
PRE E 1125 H
11
220V ~ 50 Hz
2500 W
PRE E 0720 HF
7
220
В
~ 50
Гц
1900
Вт
PRE E 0925 HF
9
220
В
~ 50
Гц
2400
Вт
PRE E 1129 HF
11
220
В
~ 50
Гц
2900
Вт
Note: Some differences between the user’s manual and the article are possible to exist, according to the
permanent process of technological modernization. We do hope that it will not cause you any inconveniences.