150
MAINTENANCE
Battery
Battery Charging
For a refresh charge, follow all instructions carefully.
1. Check the battery voltage with a voltmeter or multimeter. A fully
charged battery will register 12.8 V or higher.
2. If the voltage is less than 12.8 volts, recharge the battery at 1.2 amps
or less until the battery voltage is 12.8 or greater.
NOTE:
When using an automatic charger, refer to the charger manufacturer's
instructions for recharging. When using a constant current charger,
use the following guidelines for recharging.
NOTE:
Always verify battery condition before and 1-2 hours after the end of
charging.
WARNING
An overheated battery may explode, causing severe injury or death. Always
watch charging times carefully. Stop charging if the battery becomes very
warm to the touch. Allow it to cool before resuming charging.
State of
Charge
Voltage
Action
Charge Time
(Using constant current
charger @ standard amps
specified on top of battery)
100%
12.8-13.0 volts
None, check at 3
mos. from date of
manufacture
None required
75%-100%
12.5-12.8 volts
May need slight
charge, if no
charge given,
check in 3 months
3-6 hours
50%-75%
12.0-12.5 volts
Needs charge
5-11 hours
25%-50%
11.5-12.0 volts
Needs charge
At least 13 hours,
verify state of charge
0%-25%
11.5 volts or less
Needs charge with
desulfating charger
At least 20 hours