www.polarispool.com
If the Polaris After Dark displays any of the
following actions, adjustments may be
necessary to restore performance. Refer to
the exploded par ts diagram for par t
numbers indicated in parenthesis.
Action:
The light driver does not come on.
Solution:
1. Verify that unit is turned on.
2. If using an external remote
controller to activate the
120VAC supply, make sure
that the relay controlling the
light driver is on and
supplying power.
3. Locate the Ground Fault
Circuit Interrupter (G.F.C.I.)
protecting the circuit and
verify proper operation by
following the Test and Reset
instructions on the G.F.C.I.
4. Verify that the in-line fuse (#8),
located on the chassis, is intact.
Action:
The color wheel does not rotate.
Solution:
1. Verify that the color switch
is positioned for slow or
fast operation.
2. If using a Polaris Sol
controller or other external
remote controller, make sure
the relay controlling it is on
and supplying power.
3. Check the spade connectors
on the color wheel circuit
board (#7) and verify that they
are connected properly.
Action:
The light output has dimmed
over time.
Solution:
1. Turn off the power to the light
driver and check for dirt build
up on the manifold tip, color
wheel, and heat filter. Clean
as necessary.
2. Check the universal fiber lens
to make sure it is not filled
with water. The area around
the fiber tip inside the lens
must be dry.
Action:
The light driver is turned on but
it continues to cycle on and off.
Solution:
1. With the unit operating, listen
for the cooling fan (#13). If it is
not heard, it may be blocked.
Turn off the main power to the
light driver, remove the cover,
clear the fan of any debris
and check its wiring.
Troubleshooting