background image

2

UK

Enter the Parameter Menu

1.

Unlock the control panel, if locked.

2.

Press and hold the SET

 

 button until ‘

d1

’ flashes on the display.

3.

Press the SET

 

 button repeatedly to scroll to the desired parameter (see below).

Manual Defrost

The appliance will automatically run a defrost cycle every six hours. 

To manually defrost the appliance:

1.

Press and hold the DEFROST 

 button for 5 seconds.

2.

The defrost cycle will start immediately and the Defrost LED illuminates. The defrost will last a maximum of 30 minutes.

3.

Waste water is collected in the waste water tray.

Parameter

Name

Description

Range

d1

Operating temperature

Set the operating temperature of the appliance

-2°C to 10°C

d2

Temperature 

Differential

The Temperature Differential is the allowed temperature difference above and below the 

operating temperature before the compressor starts/cuts off

0 to 20°C

d3

Temperature Range 

Set the minimum (d3) and maximum (d4) temperatures that the appliance can fluctuate 

between

-40°C

d4

95°C

d5

Compressor Activation 

Time Intervals 

Enter the minimum time interval between the compressor turning off after turning on.

0-999 seconds

d6

Maximum Temperature 

Differential Alarm

Set an alarm to sound if the temperature inside the appliance exceeds the set operating 

temperature by a specified amount

0°C-50°C

d7

Temperature 

Differential Alarm Delay Set a delay before the temperature differential alarm is triggered

0-99 minutes

d8

Defrost Cycle Time 

Intervals

Set the time between each defrost cycle

1-999 hours

d9

Maximum Defrost 

Duration

Set the maximum length of the defrost cycle

Note: The defrost duration can be overridden by parameter d10 (below), if the 

cut-off temperature is reached before the end of the defrost duration

0-999 minutes

d10

Defrost Cut-off 

Temperature 

Set the defrost cut-off temperature

-45°C to 50°C

d11

Additional Cut-off 

Defrost Period 

Set an additional amount of defrost time after the defrost cut-off point has been reached (if 

required)

0-99 minutes

d12

Delayed Actual 

Temperature Display

Set the length of time the inner temperature of the appliance (before defrost started) is 

displayed for after a defrost cycle has finished

0-99 minutes

d13

Compressor On/Off 

During Defrost 

Turn the Compressor On or Off during the defrost cycle

On (

1

) or Off (

0

)

d14

Evaporator Drying Time

Set the amount of time the compressor remains turned Off after a defrost cycle, reducing the 

amount of frost build up

0-99 minutes

=

19

Temperature Offset

Should there be any variance between measured and actual temperature, the measured 

temperature can be offset to compensate

-20°C to 20°C

=

22

Unit of Measurement

Set whether the temperature is displayed in Centigrade or Fahrenheit

Centigrade (

0

) or Fahrenheit (

1

)

=

23

Compressor Operation 

During Probe Failure

Set whether the compressor runs or remains Off during a temperature probe failure

Compressor runs (

1

)

Remains Off until fault fixed (

0

Runs intermittently with 

parameters =

24

 and =

25 

(

2

=

24

Compressor ‘On’ 

Duration

Set the length of time the compressor runs during a temperature probe failure

1-99 minutes

=

25

Compressor ‘Off’ 

Duration

Set the length of time the compressor remains Off during a temperature probe failure

1-99 minutes

=

34

Initial Defrost After 

Startup 

Set whether the appliance starts a defrost cycle 10 minutes after startup or after the time 

programmed in parameter 

d8

 (Defrost Cycle Time Intervals)

Begins 10 minutes after startup 

(

0

) or when programmed (

1

)

=

38

Minimum Temperature 

Alarm

Set the display to flash should the inner temperature of the appliance drop beyond a specified 

point from the programmed operating temperature

1°C to 50°C

Note: The cycle starts from the time the appliance is initially powered up.

Note: Starting a manual defrost also resets the automatic defrost timer. 
The next automatic defrost will start six hours after the manual defrost has finished.

Summary of Contents for u631

Page 1: ...U631 Stainless Steel Fish Refrigerator ...

Page 2: ...eration 1 Lock Unlock the Doors 1 Storing Food 1 Turn On 1 Control Panel 1 Lock Unlock the Control Panel 1 Enter the Parameter Menu 2 Manual Defrost 2 Cleaning Care Maintenance 3 Cleaning the Condenser 3 Troubleshooting 3 Error Messages 4 Electrical Wiring 4 Disposal 4 Compliance 4 ...

Page 3: ...R dealer immediately Installation 1 Remove the appliance from the packaging Make sure that all protective plastic film and coatings are thoroughly removed from all surfaces 2 Maintain a distance of 20cm 7 inches between the unit and walls or other objects for ventilation Increase this distance if the obstacle is a heat source 3 Set the brakes on the castors to keep the appliance in position Operat...

Page 4: ... d11 Additional Cut off Defrost Period Set an additional amount of defrost time after the defrost cut off point has been reached if required 0 99 minutes d12 Delayed Actual Temperature Display Set the length of time the inner temperature of the appliance before defrost started is displayed for after a defrost cycle has finished 0 99 minutes d13 Compressor On Off During Defrost Turn the Compressor ...

Page 5: ...e plug has blown Replace the fuse Power supply Check power supply Internal wiring fault Call POLAR agent or qualified Technician The appliance turns on but the temperature is too high low Too much ice on the condenser Defrost the appliance Condenser blocked with dust Call POLAR agent or qualified Technician Doors are not shut properly Check doors are shut and seals are not damaged Appliance is loc...

Page 6: ...POLAR helpline for details of national disposal companies within the EU Compliance POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international independent and federal authorities POLAR products have been approved to carry the following symbol Error Message flashing Cause Appliance Response Action HtA The inner temperature e...

Page 7: ...Notes ...

Page 8: ...POLAR Telephone Helpline 44 0845 146 2887 POLAR Fourth Way Avonmouth United Kingdom BS11 8TB ...