background image

2

UK

To unlock the control panel:

1.

Press and hold the UP 

 and DOWN

 

 buttons simultaneously for 10 

seconds.

2.

Pon

 flashes on the display and the keyboard is unlocked.

Enter the Parameter Menu

1.

Unlock the control panel, if locked.

2.

Press and hold the SET

 

 button until ‘

d1

’ flashes on the display.

3.

Press the SET

 

 button repeatedly to scroll to the desired parameter 

(see below).

.

Manual Defrost

The appliance will automatically run a defrost cycle every six hours. 

To manually defrost the appliance:

1.

Press and hold the DEFROST 

 button for 5 seconds.

2.

The defrost cycle will start immediately and the Defrost LED illuminates. 
The defrost will last a maximum of 30 minutes.

3.

The next automatic defrost will start six hours after the manual defrost 
has finished.

Note: 
If a button is not pressed for 10 seconds while using the 
control panel it times out and reverts to standby mode.
When parameters are being set the Setpoint LED will flash on 
the display.

Parameter

Name

Description

Range

d1

Operating temperature

Set the operating temperature of the appliance

-2°C to 10°C

d2

Temperature 

Differential

The Temperature Differential is the allowed temperature difference above and below the 

operating temperature before the compressor starts/cuts off

0 to 20°C

d3

Temperature Range 

Set the minimum (d3) and maximum (d4) temperatures that the appliance can fluctuate 

between

-40°C

d4

95°C

d5

Compressor Activation 

Time Intervals 

Enter the minimum time interval between the compressor turning off after turning on.

0-999 seconds

d6

Maximum Temperature 

Differential Alarm

Set an alarm to sound if the temperature inside the appliance exceeds the set operating 

temperature by a specified amount

0°C-50°C

d7

Temperature 

Differential Alarm Delay Set a delay before the temperature differential alarm is triggered

0-99 minutes

d8

Defrost Cycle Time 

Intervals

Set the time between each defrost cycle

1-999 hours

d9

Maximum Defrost 

Duration

Set the maximum length of the defrost cycle

Note: The defrost duration can be overridden by parameter d10 (below), if the 

cut-off temperature is reached before the end of the defrost duration

0-999 minutes

d10

Defrost Cut-off 

Temperature 

Set the defrost cut-off temperature

-45°C to 50°C

d11

Additional Cut-off 

Defrost Period 

Set an additional amount of defrost time after the defrost cut-off point has been reached (if 

required)

0-99 minutes

d12

Delayed Actual 

Temperature Display

Set the length of time the inner temperature of the appliance (before defrost started) is 

displayed for after a defrost cycle has finished

0-99 minutes

d13

Compressor On/Off 

During Defrost 

Turn the Compressor On or Off during the defrost cycle

On (

1

) or Off (

0

)

d14

Evaporator Drying Time

Set the amount of time the compressor remains turned Off after a defrost cycle, reducing the 

amount of frost build up

0-99 minutes

=

19

Temperature Offset

Should there be any variance between measured and actual temperature, the measured 

temperature can be offset to compensate

-20°C to 20°C

=

22

Unit of Measurement

Set whether the temperature is displayed in Centigrade or Fahrenheit

Centigrade (

0

) or Fahrenheit (

1

)

=

23

Compressor Operation 

During Probe Failure

Set whether the compressor runs or remains Off during a temperature probe failure

Compressor runs (

1

)

Remains Off until fault fixed (

0

Runs intermittently with 

parameters =

24

 and =

25 

(

2

=

24

Compressor ‘On’ 

Duration

Set the length of time the compressor runs during a temperature probe failure

1-99 minutes

=

25

Compressor ‘Off’ 

Duration

Set the length of time the compressor remains Off during a temperature probe failure

1-99 minutes

=

34

Initial Defrost After 

Startup 

Set whether the appliance starts a defrost cycle 10 minutes after startup or after the time 

programmed in parameter 

d8

 (Defrost Cycle Time Intervals)

Begins 10 minutes after startup 

(

0

) or when programmed (

1

)

=

38

Minimum Temperature 

Alarm

Set the display to flash should the inner temperature of the appliance drop beyond a specified 

point from the programmed operating temperature

1°C to 50°C

Note: The cycle starts from the time the appliance is initially 
powered up.

Note: Starting a manual defrost also resets the automatic 
defrost timer. 

Summary of Contents for G596

Page 1: ...Stainless Steel Counter Refrigerators Freezers Models G596 G597 G598 G599 G600 G601 G621 G622 U636 U637 U638 ...

Page 2: ... 1 Fitting the Shelves Floor Guards 1 Operation 1 Storing Food 1 Turn On 1 Control Panel 1 Lock Unlock the Control Panel 1 Enter the Parameter Menu 2 Manual Defrost 2 Cleaning Care Maintenance 3 Cleaning the Condenser 3 Disposal 3 Troubleshooting 3 Error Messages 4 Electrical Wiring 4 Compliance 4 ...

Page 3: ...ng is included POLAR prides itself on quality and service ensuring that at the time of packaging the contents are supplied fully functional and free of damage Should you find any damage as a result of transit please contact your POLAR dealer immediately Installation 1 Remove the appliance from the packaging Make sure that all protective plastic film and coatings are thoroughly removed from all sur...

Page 4: ...e The defrost duration can be overridden by parameter d10 below if the cut off temperature is reached before the end of the defrost duration 0 999 minutes d10 Defrost Cut off Temperature Set the defrost cut off temperature 45 C to 50 C d11 Additional Cut off Defrost Period Set an additional amount of defrost time after the defrost cut off point has been reached if required 0 99 minutes d12 Delayed...

Page 5: ...ot working The unit is not switched on Check the unit is plugged in correctly and switched on Plug and lead are damaged Call POLAR agent or qualified Technician Fuse in the plug has blown Replace the fuse Power supply Check power supply Internal wiring fault Call POLAR agent or qualified Technician The appliance turns on but the temperature is too high low Too much ice on the condenser Defrost the...

Page 6: ...erature exceeds the set minimum temperature Display flashes Alternating error message and current temperature Check Troubleshooting Guide If problem persists call POLAR agent or qualified Technician PF1 Short circuit or interruption of the thermostat probe input line Display flashes Compressor operates as specified by parameter 23 PF2 Short circuit or interruption of the evaporator probe input lin...

Page 7: ...Notes ...

Page 8: ...POLAR Telephone Helpline 44 0845 146 2887 POLAR Fourth Way Avonmouth United Kingdom BS11 8TB ...

Reviews: