When the temperature measured by the pin probe reaches the chilling endpoint temperature:
- the device switches to storage mode
- the LED
will continue to flash and the LED
will stay on
- the display will show the message "End"
- the buzzer will sound for the period of time set by parameter AA
- press any key to mute the buzzer; press once more to cancel the message "End".
During storage:
the display shows the cabinet temperature
if chilling had a positive outcome, the LEDs
and
and will be on; if chilling had a negative
outcome, the LEDs
and
will be on and the LED
will flash
the parameter r9 sets the operational set point
press
several times to:
- display the message "PoS"
- exit the procedure, or leave for 15 s.
To interrupt the cycle:
press
for2 seconds.
SET-TEMPERATURE NEGATIVE CHILLING AND STORAGE CYCLE
To start the cycle:
ensure the device is in "stand-by" mode and no procedures are running
press
to select "nEg" and ensure the LED
is flashing
press
or
within 15 seconds: the display will show the blast chilling end- point
temperature
press
or
within 15 s to change the value (the setting re- mains active until another cycle
is selected, when the value assigned by parameter r4 is restored)
press
: after 2 minutes , run set-temperature negative chilling and storage cycle
Prior to starting the cycle:
the test is run in order to check correct pin probe insertion
- if the outcome of the test is positive, the cycle will be started
- if the outcome of the test is positive, the cycle will be started.
During chilling:
the display shows the temperature measured by the pin probe
the LED
is on
the parameter r4 sets the chilling endpoint temperature
the parameter r6 sets the maximum chilling time duration
the parameter r8 sets the operational set point
press
several times to:
- display the maximum residual chilling time remaining
- display the message "nEg"
- flashing display the cabinet temperature
- exit the procedure, or leave for 15 seconds