Troubleshooting

If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR retailer

.

Technical Specifications

Electrical Wiring

The plug is to be connected to a suitable mains socket. 
POLAR appliances are wired as follows:
•  Live wire (coloured brown) to terminal marked L
•  Neutral wire (coloured blue) to terminal marked N
•  Earth wire (coloured green/yellow) to terminal marked E 
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must 
be readily accessible.

Fault

Probable Cause

Action

The appliance is not 
working

The unit is not switched on

Check the unit is plugged in correctly and switched on

Plug and lead are damaged

Call POLAR agent or qualified Technician

Fuse in the plug has blown

Replace the fuse

Power supply

Check power supply

Internal wiring fault

Call POLAR agent or qualified Technician

The appliance turns on, 
but the temperature is 
too high/low

Too much ice on the evaporator

Defrost the appliance

Condenser blocked with dust

Call POLAR agent or qualified Technician

Doors are not shut properly

Check doors are shut and seals are not damaged

Appliance is located near a heat source or air 
flow to the condenser is being interrupted

Move the refrigerator to a more suitable location

Ambient temperature is too high

Increase ventilation or move appliance to a cooler position

Unsuitable foodstuffs are being stored in the 
appliance

Remove any excessive hot foodstuffs or blockages to the fan

Appliance is overloaded

Reduce the amount of food stored in the appliance

The appliance is leaking 
water

The appliance is not properly levelled

Adjust the screw feet to level the appliance (if applicable)

The discharge outlet is blocked

Clear the discharge outlet 

Movement of water to the drain is 
obstructed

Clear the floor of the appliance (if applicable)

The water container is damaged

Call POLAR agent or qualified Technician

The drip tray is full

Empty the drip tray (if applicable)

The appliance is 
unusually loud

Loose nut/screw

Check and tighten all nuts and screws

The appliance has not been installed in a 
level or stable position

Check installation position and change if necessary

Model

Voltage

Power

Current

Temp

Range

Capacity

(litres)

Refrigerant

Dimensions

H x W x D (mm)

Weight 

(Kg)

CE210-A

230V 50Hz 

230W

1.5A

-25 to -18C

390

R134a 210g

852 x 1330 x 701

63

CE211-A

230V 50Hz

230W

1.5A

-25 to -18C

466

R134a 210g

830 x 1483 x 701

66

CE212-A

230V 50Hz

230W

2.3A

-25 to -18C

598

R134a 210g

934 x 1603 x 733

85

Summary of Contents for CE210-A

Page 1: ...Model CE210 A CE211 A CE212 A Chest Freezer Instruction manual ...

Page 2: ...cal position and move by holding the base of the appliance Always switch off and disconnect the power supply to the unit before cleaning Keep all packaging away from children Dispose of the packaging in accordance with the regulations of local authorities If the power cord is damaged it must be replaced by a POLAR agent or a recommended qualified technician in order to avoid a hazard Product Descr...

Page 3: ...esired temperature Defrost BUFFALO recommend defrosting the appliance when any frost buld up inside the freezer reaches 5mm thick To do this switch the freezer off at the power supply Cleaning Care Maintenance Switch off and disconnect from the power supply before cleaning Clean the interior of the appliance as often as possible Do not use abrasive cleaning agents These can leave harmful residues ...

Page 4: ...qualified Technician Doors are not shut properly Check doors are shut and seals are not damaged Appliance is located near a heat source or air flow to the condenser is being interrupted Move the refrigerator to a more suitable location Ambient temperature is too high Increase ventilation or move appliance to a cooler position Unsuitable foodstuffs are being stored in the appliance Remove any exces...

Page 5: ...esponsible for waste disposal in your area POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international independent and federal authorities POLAR products have been approved to carry the following symbol All rights reserved No part of these instructions may be produced or transmitted in any form or by any means electronic me...

Page 6: ... Freezers Model CE210 A CE211 A CE212 A Legislation C Tick AS NZ 3820 Essential Safety Requirements for Low Voltage Electrical Equipment Standards AS NZS CISPR 14 1 2010 AS NZS 60335 2 89 2002 Inc A1 3 Producer Name POLAR Producer Address Unit 2 34 38 Anzac Ave Smeaton Grange NSW 2567 Date 13 11 12 Signature Full Name Richard Cromwell Position Marketing Director ...

Page 7: ... Notes ...

Page 8: ...CE210 A_CE211 A_C212 A_v1 ...

Reviews: