4
UK
Telephone Helpline
: 0845 146 2887 (United Kingdom)
Technical Specifications
The appliance turns
on, but the
temperature is too
high/low
Too much ice on the
condenser
Defrost the appliance
Condenser blocked with
dust
Call POLAR agent or qualified Technician
Doors are not shut
properly
Check doors are shut and seals are not damaged
Appliance is located near
a heat source or air flow
to the condenser is being
interrupted
Move the refrigerator to a more suitable location
Ambient temperature is
too high
Increase ventilation or move appliance to a cooler position
Unsuitable foodstuffs are
being stored in the
appliance
Remove any excessive hot foodstuffs or blockages to the fan
Appliance is overloaded
Reduce the amount of food stored in the appliance
The appliance is
leaking water
The appliance is not
properly levelled
Adjust the screw feet to level the appliance (if applicable)
The discharge outlet is
blocked
Clear the discharge outlet
Movement of water to the
drain is obstructed
Clear the floor of the appliance (if applicable)
The water container is
damaged
Call POLAR agent or qualified Technician
The appliance is
unusually loud
Loose nut/screw
Check and tighten all nuts and screws
The appliance has not
been installed in a level or
stable position
Check installation position and change if necessary
Model
Voltage
Power
Current
Temperature
Range
Capacity
(litres)
Refrigerant
Dimensions
H x W x D
(mm)
Weight
(Kg)
CD610
230V
50Hz
100
0.7A
-2°C to 8°C
150
R134a
(80g)
850 x 600 x
600
55
CD611
230V
50Hz
130
1.1A
-10°C to -25°C
140
R404a
(110g)
850 x 600 x
600
60
CD612
230V
50Hz
150
1.4A
-2°C to 8°C
400
R134a
(140g)
1850 x 600 x
600
90
CD613
230V
50Hz
180
1.6A
-10°C to -25°C
365
R404a
(165g)
1850 x 600 x
600
100
CD614
230V
50Hz
180
1.6
-2°C to 8°C
600
R134a
(195g)
1900 x 777 x
690
135
CD615
230V
50Hz
300
2.5
-10°C to -25°C
600
R404a
(230g)
1900 x 777 x
690
150