Troubleshooting
Fault
Probable Cause
Solution
Refrigeration not
working
Electricity not turned on
Switch on electricity at socket
Plug fuse blown
Replace fuse
Multideck is switched off
Turn switch to on position so it lights up
Poor refrigeration
performance
High ambient temperature
Ventilate room or area around Multideck
Poor ventilation
Increase air flow around Multideck
Too much food in the Showcase is
preventing cold air circulating
Take out some food
Condenser need to be cleaned
Call Polar service agent
Multideck is not level
Adjust position to level
Showcase is noisy
when turned on
Multideck is too close to a wall or
other object
Move position
Technical Specifications
Model
Voltage
Power
Current
Capacity
(Litres)
Refrigerant
Dimensions
H x W x D mm
CD239
230V 50Hz
1300W
6.7A
220
R290 (143g)
1742 x 494 x 674
Weight Operating Temperature
Range
Default Temperature
Setting
Defrost Interval
Default Setting
96kg
2-12°C
2°C
6 hours
CD239_ML_A5_v2_171215.indb 5