Polar Electro G608-A Instruction Manual Download Page 2

2

AU

Telephone Helpline: 1300225960

Safety Tips

•  Position on a flat, stable surface.
•  A service agent/qualified technician should carry out 

installation and any repairs if required. Do not remove any 
components or service panels on this product.

•  Consult Local and National Standards to comply with the 

following:

  - Health and Safety at Work Legislation
  - Fire Precautions
  - Wiring Regulations
  - Building Regulations
•  DO NOT use jet/pressure washers to clean the appliance.
•  DO NOT use the appliance outside.
•  DO NOT use this appliance to store medical supplies.
•  Always carry, store and handle the appliance in a vertical 

position and move by holding the base of the appliance.

•  Always switch off and disconnect the power supply to the unit 

before cleaning.

•  Keep all packaging away from children. Dispose of the 

packaging in accordance with the regulations of local 
authorities.

•  If the power cord is damaged, it must be replaced by a POLAR 

agent or a recommended qualified technician in order to avoid 
a hazard.

•  This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental capabilities, 
or lack of experience or knowledge, unless they have been 
given supervision or instruction concerning the use of the 
appliance by a person responsible for their safety.

GD875-A_GD876-A_GD877-A_A5_v5_20191129.indb   2

GD875-A_GD876-A_GD877-A_A5_v5_20191129.indb   2

2021/2/1   14:39

2021/2/1   14:39

Summary of Contents for G608-A

Page 1: ...A GD876 A GD877 A Stainless Steel Counter Top Servery Prep Refrigerators Instruction manual GD875 A_GD876 A_GD877 A_A5_v5_20191129 indb 1 GD875 A_GD876 A_GD877 A_A5_v5_20191129 indb 1 2021 2 1 14 39 2021 2 1 14 39 ...

Page 2: ...al position and move by holding the base of the appliance Always switch off and disconnect the power supply to the unit before cleaning Keep all packaging away from children Dispose of the packaging in accordance with the regulations of local authorities If the power cord is damaged it must be replaced by a POLAR agent or a recommended qualified technician in order to avoid a hazard This appliance...

Page 3: ...turer Product Description GD875 A POLAR 3 x 1 3 1 x 1 2 GN Container Refrigerated Counter Top Servery Prep GD876 A POLAR 5 x 1 3 1 x 1 2 GN Container Refrigerated Counter Top Servery Prep GD877 A POLAR 8 x 1 3 GN Container Refrigerated Counter Top Servery Prep Introduction Please take a few moments to carefully read through this manual Correct maintenance and operation of this machine will provide...

Page 4: ...ll result in the glass breaking 4 Slot the rear panel into the collars with the holes in the glass at the top 5 Screw a grub screw into each collar to secure the panel 6 Slot the plastic plugs into each of the holes 7 Screw the brackets to the inside of each pane using the bolt assemblies Note Ensure the short end of the bolt assembly is on the outside of the panels 8 Place the top panel onto the ...

Page 5: ... the evaporation pan Take care when cleaning the rear of the appliance Sharp edges can cut A POLAR agent or qualified technician must carry out repairs if required Cleaning the Condenser Filter The condenser is part of the refrigeration system The condenser filter requires monthly cleaning Always disconnect power supply before carrying out Routine Maintenance Failure to clean the condenser filter ...

Page 6: ...s blocked Clear the discharge outlet Movement of water to the drain is obstructed Clear the floor of the appliance If applicable The water container is damaged Call POLAR agent or qualified Technician The drip tray is overflowing Empty the drip tray If applicable The appliance is unusually loud Loose nut screw Check and tighten all nuts and screws The appliance has not been installed in a level or...

Page 7: ...nmentally safe recycling process For further information on how to dispose of this product correctly contact the product supplier or the local authority responsible for waste disposal in your area POLAR parts have undergone strict product testing in order to comply with regulatory standards and specifications set by international independent and federal authorities POLAR products have been approve...

Page 8: ...tory Legislation Directive s and Standard s Ik de ondergetekende verklaar hierbij dat de hierboven gespecificeerde uitrusting goedgekeurd is volgens de bovenstaande Richtlijn en en Standaard en Je soussigné confirme la conformité de l équipement cité dans la présente à la aux Directive s et Norme s ci dessus Ich der die Unterzeichnende erkläre hiermit dass das oben angegebene Gerät der den oben an...

Page 9: ...GD875 A_GD876 A_GD877 A_A5_v5_20191129 indb 9 GD875 A_GD876 A_GD877 A_A5_v5_20191129 indb 9 2021 2 1 14 39 2021 2 1 14 39 ...

Page 10: ...GD875 A_GD876 A_GD877 A_A5_v5_20191129 indb 10 GD875 A_GD876 A_GD877 A_A5_v5_20191129 indb 10 2021 2 1 14 39 2021 2 1 14 39 ...

Page 11: ...GD875 A_GD876 A_GD877 A_A5_v5_20191129 indb 11 GD875 A_GD876 A_GD877 A_A5_v5_20191129 indb 11 2021 2 1 14 39 2021 2 1 14 39 ...

Page 12: ...GD875 A_GD876 A_GD877 A_A5_v5_20210201 http www polar refrigerator com GD875 A_GD876 A_GD877 A_A5_v5_20191129 indb 12 GD875 A_GD876 A_GD877 A_A5_v5_20191129 indb 12 2021 2 1 14 39 2021 2 1 14 39 ...

Reviews: