Cleaning, Care & Maintenance
• Switch off and disconnect from the power supply before cleaning.
• Clean the interior of the appliance as often as possible.
• Do not use abrasive cleaning agents. These can leave harmful residues.
• Clean the door seal with warm soapy water.
• Always wipe dry after cleaning.
• Do not allow water used in cleaning to run through the drain hole into the evaporation pan.
• Take care when cleaning the rear of the appliance. Sharp edges can cut.
Condensation will form in refrigeration with frequent opening of the doors and on hot humid
days, please ensure condensation is allowed to drain properly or is wiped dry.
Cleaning the Condenser
Periodically cleaning the condenser can extend the life of the appliance.
POLAR recommend that a POLAR agent or qualified technician should clean the condenser.
Troubleshooting
A qualified technician must carry out repairs if required.
Fault
Probable Cause
Solution
The appliance is not
working
The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug or lead is damaged
Replace Plug or lead
Fuse in the plug has blown
Replace the fuse
Mains power supply fault
Check mains power supply
The appliance turns on,
but the temperature is
too high/low
Too much ice on the evaporator
Defrost the appliance
Condenser blocked with dust
Clean the condenser
Doors are not shut properly
Check doors are shut and seals are not
damaged
Appliance is located near a
heat source or air flow to the
condenser is being interrupted
Move the refrigerator to a more suitable
location
Ambient temperature is too high
Increase ventilation or move appliance to a
cooler position
Unsuitable foodstuffs are being
stored in the appliance
Remove any excessive hot foodstuffs or
blockages to the fan
Appliance is overloaded
Reduce the amount of food stored in the
appliance
The appliance is
leaking water
The appliance is not properly
levelled
Adjust the screw feet to level the appliance
(if applicable)
The discharge outlet is blocked
Clear the discharge outlet
CD610-CD615_CD080-CD085_GL185_ML_A5_v21_20220930.indb 7
CD610-CD615_CD080-CD085_GL185_ML_A5_v21_20220930.indb 7
2022/9/30 15:36
2022/9/30 15:36