7
UK
Troubleshooting
If your POLAR appliance develops a fault, please check the following table before making a call to the
Helpline or your POLAR dealer.
Fault
Probable Cause
Solution
The appliance is not
working
The unit is not switched on
Check the unit is plugged in correctly and
switched on
Plug or lead is damaged
Call POLAR agent or qualified Technician
Fuse in the plug has blown
Replace the fuse
Power supply
Check power supply
Appliance is noisy or
works intermittently
Appliance is not level
Adjust the feet to level the appliance
Wine fridge cabinet is
not cold enough
Temperature set incorrectly
Check temperature and reset if necessary
External environment may require
colder temperature
Check temperature and reset if necessary
The door is opened too often
Only open when necessary
Door seal is worn
Call POLAR agent or qualified technician
Light is not working
Light key is not pressed
Press the light key
Bulb has blown
Call POLAR agent or qualified technician
Door will not close
properly
Appliance is not level
Adjust the feet to level the appliance
Shelves are out of position
Check all shelves are properly inserted
Door seal is dirty
Wipe clean with a damp cloth
Error code “EE” on
display
Temperature probe is short-
circuited or disconnected
Call POLAR agent or qualified technician
Error code “LL” on
display
Temperature measured by the
temperature probe is lower than
0°C (Display range: 0~37°C)
Call POLAR agent or qualified technician
Error code “HH” on
display
Temperature measured by the
temperature probe is higher than
37°C (Display range: 0~37°C)
Technical Specifications
Model
Voltage
Power
Current
Bottle
Capacity
Refrigerant
Temp.
Range
Dimensions
H x W x D mm
Weight
(kg)
CB058
220-240V~
50Hz
85W
0.6A
16
R600a 21g
5-18°C
560 x 430 x 450
17