THROUGH THE WALL UNIT 

 

14

45 

PTTW10-045 

Compressor capacitor insulation material 

46 

PTTW10-046 

Capacitor for compressor 

47 

PTTW10-047 

Basic pan 

48 

PTTW10-048 

Link plate 

49 

PTTW10-049 

Compressor mounting sheet 

50 

PTTW10-050 

Compressor bottom insulation material 

51 

PTTW10-051 

Condenser assy. 

52 

PTTW10-052 

Air outlet grill 

53 

PTTW10-053 

Evaporator assy 

54 

PTTW10-054 

Evaporator top epp 

55 

PTTW10-055 

Evaporator down epp 

56 

PTTW10-056 

Evaporator insulation material 

57 

PTTW10-057 

Partition 

58 

PTTW10-058 

Condenser top epp closer 

59 

PTTW10-059 

Condenser lower epp 

60 

PTTW10-060 

Condenser top epp 

61 

PTTW10-061 

upper acrylic panel 

62 

PTTW10-062 

down acrylic panel 

63 

PTTW10-063 

Front panel 

64 

PTTW10-064 

flap panel 

65 

PTTW10-065 

Axis sleeve 

66 

PTTW10-066 

Front panel bottom insulation material 

67 

PTTW10-067 

Front panel top insulation material 

68 

PTTW10-068 

Front panel insulation material 3 

69 

PTTW10-069 

Power cable 

70 

PTTW10-070 

Cable plastic ring 

71 

PTTW10-071 

Stopple 

72 

PTTW10-072 

Capillary assy. 

73 

PTTW10-073 

Drain parts 

74 

PTTW10-074 

Remote control 

75 

PTTW10-075 

Remote control seat 

76 

PTTW10-076 

Battery 

77 

PTTW10-077 

LED display PCB 

78 

PTTW10-078 

Speaker back plate 

79 

PTTW10-079 

Speaker fan 

80 

PTTW10-080 

Speaker fan motor 

81 

PTTW10-081 

Speaker terminal block 

82 

PTTW10-082 

Speaker PTC heater 

83 

PTTW10-083 

Speaker fan motor bracket 

84 

PTTW10-084 

Speaker cover 

85 

PTTW10-085 

Speaker warning label 

86 

PTTW10-086 

Speaker filter 

87 

PTTW10-087 

Speaker inlet grille 

88 

PTTW10-088 

Speaker outlet grille 

89 

PTTW10-089 

Speaker plastic component 

Summary of Contents for PTTW-10-EC+EH Series

Page 1: ...ENGINEERING MANUAL PTTW 10 EC EH SERIES THROUGH THE WALL HEAT PUMPS 2010 ARI V 1 5...

Page 2: ...s each year all conforming to the highest international standards of quality and safety The Highest Standards of Manufacturing In order to guarantee the very highest standards and performance we manag...

Page 3: ...an mode 7 Indoor noise test in cooling mode 8 Outdoor noise test in cooling mode 9 D Comparison between energy saving EC motor standard AC motor 10 E LCDI plug information 11 F Exploded drawing and pa...

Page 4: ...GH THE WALL UNIT 3 PTTW THROUGH THE WALL UNIT MODEL ASSIGNMENTS PTTW 1 0 EC EH EH ELECTRIC HEATER PTTW THROUGH THE WALL UNIT UNIT NOMINAL CAPACITY 10 NOMINAL 10 000 BTU H EC ELECTRONICALLY COMMUTATED...

Page 5: ...LY V Ph Hz 208 230 1 60 COOLING W 885 POWER INPUT HEATING W 830 COOLING A 4 5 RUNNING CURRENT HEATING A 4 1 COOLING A 12 3 START CURRENT HEATING A 11 6 ELECTRIC HEATER RUNNING CURRENT A 9 1 COMPRESSOR...

Page 6: ...41 1 44 4 47 6 Indoor Cooling Heating Mode 43 7 46 0 48 2 Outdoor 46 6 58 1 NB Unit noise testing is performed in a semi reverberant test chamber with ambient noise level of 23 2 dB A The indoor noise...

Page 7: ...anized steel Cover material thickness mm in 0 8 0 03 Picture Notes x The sound attenuation device is designed to reduce outdoor sound levels by silencing air and machine noise exhausted by the unit vi...

Page 8: ...THROUGH THE WALL UNIT 7 NOISE LEVEL INDOOR FAN MODE...

Page 9: ...THROUGH THE WALL UNIT 8 NOISE LEVEL INDOOR COOLING MODE...

Page 10: ...THROUGH THE WALL UNIT 9 NOISE LEVEL OUTDOOR COOLING MODE...

Page 11: ...n motor Rpm per 1W power input 15 6 PTTW 10 EC PTTW 12 Cooling capacity 2 9 3 2 Cooling power input 885 1315 Cooling power input per 3414BTU 1kW capacity 305 411 Heating capacity 2 95 3 4 Heating powe...

Page 12: ...exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power...

Page 13: ...THROUGH THE WALL UNIT 12 EXPLODED DRAWING...

Page 14: ...10 020 Fresh air pipe 1 21 PTTW10 021 O ring for air inlet pipe 1 22 PTTW10 022 O ring for air outlet pipe 1 23 PTTW10 023 On board control box film 1 24 PTTW10 024 On board control box 1 25 PTTW10 02...

Page 15: ...nel 1 64 PTTW10 064 flap panel 1 65 PTTW10 065 Axis sleeve 1 66 PTTW10 066 Front panel bottom insulation material 1 67 PTTW10 067 Front panel top insulation material 1 68 PTTW10 068 Front panel insula...

Page 16: ...15 DIMENSIONAL DRAWINGS PTTW 10 EC EH NB The external pipes have two different diameters use 6 30in for air outlet side see red arrow and 5 90in for air inlet side see blue arrow WALL BRACKET NB all u...

Page 17: ...THROUGH THE WALL UNIT 16 ELECTRIC WIRING DIAGRAM For PTTW 10 EC EH...

Page 18: ...eaning Disconnect the heat pump from the electrical supply Wipe external surfaces clean with a damp cloth only Do not use an abrasive cloth and or solvents as this may damage the surfaces Do not use a...

Page 19: ...eeds to be removed from the unit and exposes under the sun light for every one or two months depend on the indoor air quality The filter should be replaced every two to three years 13 5 Position of el...

Page 20: ...lways operate the product from a power source of the same voltage frequency and rating as indicated on the product identification plate This heat pump is not intended for use in wet or damp locations...

Page 21: ...ing Function Timer ON Timer OFF Electric heater ON OFF and Sleep Function 2 1 2 ON BOARD PANEL FUNCTIONS On board panel functions are Unit ON OFF Mode Fan Speed Set Temperature and Electric heater ON...

Page 22: ...ed When RT ST 1 8 F middle speed changes to low speed Fan speed High speed Middle speed Low speed 1 8 F 1 8 F 3 6 F 9 0 F RT ST 2 2 3 DEHUMIDIFICATION MODE 2 2 3 1 Setting temperature 64 4 F 86 F 2 2...

Page 23: ...ed on the four way valve will open 5 minutes before compressor starts When mode is changed from heating mode or unit is turned off four way valve will close after compressor has stopped for 2 minutes...

Page 24: ...2 2 5 2 FOUR WAY VALVE DEFROST FUNCTION a Defrost starting conditions In heating mode when the unit has been heating for 30 minutes or more and the compressor is continuously running for 5 minutes the...

Page 25: ...lectric heater function manual ON OFF When the unit is under heating mode press the electric heater power button from on board control panel or IR handset to activate the electric heater functionality...

Page 26: ...sor and outdoor fan will start normally Indoor fan motor will run in low speed The four way valve will be closed If room temperature setting temperature the unit will start sleep mode Fan speed will b...

Page 27: ...reducing key to adjust the time The temperature rising key is for one hour press it and it will increase in one hour steps The temperature reducing key is for minutes press it and it will increase in...

Page 28: ...THROUGH THE WALL UNIT 27...

Page 29: ...utdoor fan motor start again and exit the anti freeze protection state 2 6 3 Over heat protection in heating mode In heating mode a When IPT 131 F outdoor fan motor will stop b When IPT 118 4 F outdoo...

Page 30: ...l display E3 on the panel 2 6 6 Refrigerant insufficient protection In cooling mode or cooling in auto mode compressor operators for 20 minutes if indoor coil temperature room temperature 9 F and time...

Page 31: ...1 4 0 733 32 14 2293 82 4 4 4569 132 8 1 6663 183 2 0 713 33 8 13 6017 84 2 4 2912 134 6 1 6131 185 0 693 35 6 13 0055 86 4 1327 136 4 1 5618 186 8 0 674 37 4 12 4391 87 8 3 9808 138 2 1 5123 188 6 0...

Page 32: ...ait for a few minutes until the temperature adjusts The temperature is not properly set check it The grilles could be obstructed check and remove any obstacles Wrong installation of the heat pump Wron...

Page 33: ...THROUGH THE WALL UNIT 32 THIS IS THE END...

Reviews: