How to use PoPendant and PoKeys in
Mach
Page 1: ...How to use PoPendant and PoKeys in Mach ...
Page 2: ...ww poscope com Contents 1 PoKeys configuration 3 2 PoKeys and PoPendant connection 4 3 Mach configuration 5 4 Using LCD from Mach 9 4 1 Connecting LCD to PoKeys 9 4 2 PoKeys software configuration 10 4 3 Settings in Mach 12 5 Grant of license 16 ...
Page 3: ...oKeys software from www poscope com Yes it is in PoKeys department of web page Open software and upgrade firmware if it asks for Be patient upgrade can take some time Figure 1 Open configuration Go to File Open Figure 1 and find PoKeys configuration file which you downloaded from www poscope com Click send to device and close PoKeys software ...
Page 4: ... black MPG GND GND 3 green MPG A 1 4 white MPG B 2 3 purple N C N C 4 purple black N C N C 5 green black Lamp N C 6 white black Lamp GND 7 yellow X axis 36 8 yellow black Y axis 25 9 brown Z axis 26 10 brown black A axis 10 9 pink B axis 11 10 pink black C axis 12 11 gray x1 7 12 gray black x10 8 13 orange x100 9 14 orange black Ctrl Switch GND 15 Light blue Estop 35 16 blue black Estop GND GND 17...
Page 5: ...ope com 3 Mach configuration Download and install latest PoKeys plugin for Mach from www poscope com Yes it is in PoKeys department of web page Run Mach an follow manual Figure 3 Config Plugins Figure 4 Tick near PoKeys0 Figure 5 Config Ports and Pins ...
Page 6: ...How to use PoPendant and PoKeys in Mach 6 www poscope com Figure 6 Chack marked MPG settings and click OK Figure 7 Config General Config ...
Page 7: ...How to use PoPendant and PoKeys in Mach 7 www poscope com Figure 8 Check values in Jog Increments in Cycle mode then hit OK Now close and open Mach Figure 9 PlugIn Control PoKeys0 Cfg ...
Page 8: ...Check marked values and click Config Pendant Analog Jogging Configuration Figure 11 Set marked options and click OK OK Close and open Mach Now your Pendant should work Choose axis and multiplier and press Controll switch on pendant Now you can turn MPG and move machine ...
Page 9: ...stor between GND and supply or PWM output 4 RS Instruction data input Pin 29 5 R W Read write Pin 28 6 E Enable signal Pin 30 7 DB0 Data bus bit 0 Not connected 8 DB1 Data bus bit 1 Not connected 9 DB2 Data bus bit 2 Not connected 10 DB3 Data bus bit 3 Not connected 11 DB4 Data bus bit 4 Pin 26 or secondary 34 12 DB5 Data bus bit 5 Pin 25 or secondary 33 13 DB6 Data bus bit 6 Pin 24 or secondary 3...
Page 10: ...t and PoKeys in Mach 10 www poscope com 4 2 PoKeys software configuration After PoKeys and LCD are connected connect PoKeys to USB and run PoKeys software These window is opened Choose your device and press connect button ...
Page 11: ...settings are done Number of rows Number of columns Enable LCD support Secondary pins We choosed 4x20 characters LCD Connected as secondary LCD After that click on Initialize LCD button Close window and if you followed manual you should see something like these As seen on the picture active pins are 28 34 At the end configuration must be saved to PoKeys with Send to device button and close PoKeys s...
Page 12: ...om 4 3 Settings in Mach Download and run Mach plugin which should be downloaded from http www poscope com Run Mach Choose Config Configplugins and enable PoKeys as shown on picture bellow Click OK close Mach and run it again Go to PlugIn Control PoKeys0 Cfg ...
Page 13: ...characters are set 4x20 LCD recomended Tick Use LCD Display pins 28 34 and made all settings exactly as in green field of upper picture When the condition UserLED on is fullfild QuickPickRow fields are writing us user defined texts In these fields any message can be written in our case UserLED 2001 2004 ...
Page 14: ...m Restart Mach again and enable Run Macro Pump in General LogicConfiguration window In menu Operator choose VB Editor in which script which will show datas on the LCD will be written These is example of very simple script which shows us axis positions on LCD ...
Page 15: ...will fire off that message When the light is LED is ON then the message you put on the quick pick line will display on the LCD Quick pick example is this if you tick use quick pick row line1 and have it watch LED 800 800 is the Estop OEM LED and you put in the message box Estop is Active then when ever mach is in estop then the message will display on line 1 If you want to have Text contrast and B...
Page 16: ...pose No two applications are the same so PoLabs cannot guarantee that its equipment methods or software is suitable for a given application It is therefore the user s responsibility to ensure that the product is suitable for the user s application Mission Critical applications Because the software runs on a computer that may be running other software products and may be subject to interference fro...
Page 17: ...How to use PoPendant and PoKeys in Mach 17 www poscope com support www poscope com ...