![POLA HP53 Handbook Download Page 1](http://html1.mh-extra.com/html/pola/hp53/hp53_handbook_1570917001.webp)
HP53
MAIN SETTINGS (Run Mode)
VENTILATION TEMPERATURE SETTING.
Press
°C VENT
:
This message will be displayed instead of the
°Set
Ventilation temperature value
(start first speed)
.
Press
+
or
-
to modify, press
°C VENT
to confirm.
MINIMUM SPEED SETTING.
Press
MIN VENT
:
This message will be displayed instead of the
Minimum Ventilation Speed.
Press
+
or
-
to modify, press
MIN
to confirm.
MAXIMUM SPEED SETTING.
Press
MAX VENT
:
This message will be displayed instead of the
Maximum Ventilation Speed.
Press
+
or
-
to modify, press
MAX
to confirm.
In normal condition ambient temperature is displayed and in setting coindition
flashing message appear.
The normal condition become again after exit from setting mode (auto-exit is
performed after 5 seconds from last key stroke in setting condition).
Press
+
:
will be displayed followed by
°Maximum Temperature Recording.
Press
-
:
will be displayed followed by
°Minimum Temperature Recording.
VIEWING TEMPERATURE RECORDING
Values recorder are memory permanent stored: for memory clear keep pushed
+
keys for more than 3 seconds:
CLEA
message will be composed on display before
clearing operation.
AMBIENT TEMPERATURE VIEWING
How to connect the sensors
Connect the temperature probe provided as shown in the diagram. For remote
connections use a standard 0.5-square millimeter two-pole wire for each sensor,
taking great care over the connections, by insulating and sealing the joins
carefully.
How to connect the line
Connect 220V line on terminals
L-N
.
How to connect the contacts
Connect terminals
3-7
/
...11-13
on the terminal block (contacts up to 4AMP.AC1).
Output contacts are N.O. (Normally Opened and free of voltage) on wich is
aplliable a 4AMP AC1 maximum load.
3-4= Speed 1 contact.
3-5= Speed 2 contact.
3-6= Speed 3 contatc.
3-7= Speed 4 contact.
11-12= Heat contact.
12-13= Cool contact
INSTALLATION
PRESET PROGRAMS
At delivery this processor is ready programmed with the following (variable)
settings. To return to these settings at any time:
Power off the processor, press
MAX VENT
key and keep it pressed giving
power on:
boot
message will be displayed (release now
MAX VENT
key).
°C VENT=25.0° MIN VENT=0 MAX VENT=4
The
COSt
values are shown in
COSt
paragraphs.
Handbook
Steps-Controller
SL 2.0
.
HP53
FUSE 4A T
H=1500A
H=1500A
FUSE 4A T
230V LINE *
COMMON
SPEED 4
SPEED 3
SPEED 2
SPEED 1
TEMPER. PROBE
COOL
COMMON.
HEAT
*
Other power voltage if you required
As it company policy to continually improve the products the Manufacturers
reserve the right to make any modifications thereto without prior notice. They
cannot be held liable for any damage due to malfunction.
19.07.06