-3-
HEAT TEMPERATURE SETTING.
MINIMUM SPEED VENTILATION SETTINGS.
Press MIN VENT :
This messagge will be displayed instead of the
°Minimum Ventilation Speed.
Press + or - to modify, press MIN VENT to exit.
MAIN SETTINGS (Run Mode)
HEAT TEMPERATURE SETTING.
Press HEAT (key lamp flashes):
This messagge will be displayed instead of the
°Set Heat temperature value
.
Press + or - to modify, press HEAT to exit.
VENTILATION TEMPERATURE SETTING.
Press °C VENT (key lamp flashes):
This messagge will be displayed instead of the
°Set Ventilation temperature value
(start first speed)
.
Press + or - to modify, press VENT to confirm.
If the minimum speed is set to
0
, this messagge appears instead
of the
Set Shutter Running Time
(in seconds or in minutes*).
Press + or - to modify, press VENT to confirm.
At this point: this messagge will be displayed instead of the
Shutter Dwell Time
(in seconds or in minutes*).
Press + or - to modify, press VENT to confirm.
At this point: this messagge will be displayed instead of the
Shut Speed Number.
Press + or - to modify, press VENT to exit.
MAXIMUM SPEED VENTILATION SETTINGS.
Press MAX VENT :
This messagge will be displayed instead of the
°Maximum Ventilation Speed.
Press + or - to modify, press MAX VENT to exit.
COOLING TEMPERATURE SETTINGS.
Press COOL :
This messagge will be displayed instead of the
°Set Cool temperature value.
Press + or - to modify, press COOL to exit.
PRESET PROGRAMS (Bootstrap)
At delivery this processor is ready programmed with the following (variable)
settings.
To return to these settings at any time.
Press + / - / ALARM keys together for at least one second:
boot
messagge will be displayed.
HEAt
= 20.0°
vEnt
= 25.0°
t.on=10" t.OF= 60" PArt
= 0
SP._ _
= 0
SP.-- = 6 COOL=30.0° AL._ _
= 10.0°
AL.- -
= 40.0°
COST value are shown in COST paragraph.
STATUS INDICATION LAMPS
The lights situated at the bottom of the display show the state of the various relays
as set out below.
Lamp
State
N° Relay
Output contacts
HEAT
HEAT On
HPAL 1/HDY6 1
HPAL 3-4/HDY6 3-4
VENT 1
SPEED 1
HD38-1
HD38 3-5
VENT 2
SPEED 2
HD38-2
HD38 3-6
VENT 3
SPEED 3
HD38-3
HD38 3-7
VENT 4
SPEED 4
HD38-4
HD38 3-8
VENT 5
SPEED 5
HD38-5
HD38 3-9
VENT 6
SPEED 6
HD38-6
HD38 3-10
COOL
COOL On
HDY6 2
HDY6 5-6
AL. MIN
MINIMUM ALARM On
HPAL 2/HDY6 3
HPAL 7-8/HDY6 7-8
AL. MAX
MAXIMUM ALARM On
HPAL 2/ HDY6 3
HPAL 7-8/HDY6 7-8
Relative light ( 1-2-3-4-5-6) flash during VENT time cycling, or during
r.vEn
(see
COSt) time delay.
* See Cost,
tinE
function.
"HAND MODE"
In some start-up conditions may be useful to work in "hand" mode.
Press + / - / MIN VENT keys together for least one second:
HAnd
messagge will be displayed (release now + key).
Push + until is displayed number required to be handed (see table relays "N°
Relay") and push ALARM for activing relay.
Pushing again + for increase relay number previous relay is disactivated.
You can press MIN VENT to escape and return to the
Run Mode.