-3-

HEAT TEMPERATURE SETTING.

MINIMUM SPEED VENTILATION SETTINGS.

Press MIN VENT :
This messagge will be displayed instead of the

°Minimum Ventilation Speed.

Press or to modify, press MIN VENT to exit.

MAIN SETTINGS (Run Mode)

HEAT TEMPERATURE SETTING.
Press HEAT (key lamp flashes):
This messagge will be displayed instead of the

°Set Heat temperature value

.

Press or to modify, press HEAT to exit.

VENTILATION TEMPERATURE SETTING.

Press °C VENT (key lamp flashes):
This messagge will be displayed instead of the

°Set Ventilation temperature value

 

(start first speed)

.

Press or to modify, press VENT to confirm.

If the minimum speed is set to 

0

, this messagge appears instead

of the 

Set Shutter Running Time 

(in seconds or in minutes*).

Press or to modify, press VENT to confirm.

At this point: this messagge will be displayed instead of the

Shutter Dwell Time  

(in seconds or in minutes*).

Press or to modify, press VENT to confirm.

At this point: this messagge will be displayed instead of the

Shut Speed Number.

Press or to modify, press VENT to exit.

MAXIMUM SPEED VENTILATION SETTINGS.

Press MAX VENT :
This messagge will be displayed instead of the

°Maximum Ventilation Speed.

Press or to modify, press MAX VENT to exit.

COOLING TEMPERATURE SETTINGS.

Press COOL :
This messagge will be displayed instead of the

°Set Cool temperature value.

Press or to modify, press COOL to exit.

PRESET PROGRAMS (Bootstrap)

At delivery this processor is ready programmed with  the  following (variable)
settings.
To return to these settings at any time.
Press + / - / ALARM keys together for at least one second:

boot 

 messagge will be displayed.

HEAt

 = 20.0°

        vEnt 

= 25.0°   

     t.on=10"        t.OF= 60"        PArt

= 0

SP._ _

= 0             

SP.-- = 6             COOL=30.0°   AL._ _

10.0°  

AL.- - 

= 40.0°

COST value are shown in COST paragraph.

STATUS INDICATION LAMPS

The lights situated at the bottom of the  display  show the state of the various relays

as set out below.

Lamp

State

N° Relay

Output contacts

HEAT

HEAT On

HPAL 1/HDY6 1

HPAL 3-4/HDY6 3-4

VENT 1

SPEED 1

HD38-1

HD38 3-5

VENT 2

SPEED 2

HD38-2

HD38 3-6

VENT 3

SPEED 3

HD38-3

HD38 3-7

VENT 4

SPEED 4

HD38-4

HD38 3-8

VENT 5

SPEED 5

HD38-5

HD38 3-9

VENT 6

SPEED 6

HD38-6

 HD38 3-10

COOL

COOL On

HDY6 2

HDY6 5-6

AL. MIN

MINIMUM ALARM On

HPAL 2/HDY6 3

HPAL 7-8/HDY6 7-8

AL. MAX

MAXIMUM ALARM On

HPAL 2/ HDY6 3

HPAL 7-8/HDY6 7-8

Relative light ( 1-2-3-4-5-6) flash during VENT time cycling, or during 

r.vEn

 (see

COSt) time delay.

* See Cost, 

tinE 

function.

"HAND MODE"

In some start-up conditions may be useful to work in "hand" mode.
Press + / - / MIN VENT  keys together for least one second:

 HAnd

  messagge will be displayed (release now   key).

Push   +  until is displayed number required to be handed (see table relays "

Relay") and push ALARM for activing relay.

Pushing again  +  for increase relay number previous relay is disactivated.
You can press MIN VENT  to escape and return to the 

Run Mode.