3
User manual
En
gli
sh
Introduction
The gas detector from the PNI Safe House Dual Gas 250LR package
accurately detects carbon monoxide (CO), natural gases such as: methane,
propane, butane, ethane and gaseous hydrocarbons such as: propylene and
butylene.
Note: The gas detector in the PNI Safe House Dual Gas 250LR package does not
detect smoke, fire, or gases from other categories than those mentioned above.
The PNI Safe House Dual Gas 250LR package consists of a gas detector and
a 3/4 inch solenoid valve.
Technical specifications
Gas detector
Sensor
2 semiconductor sensors
Gas detection
Carbon monoxide (CO), natural
gas, gaseous hydrocarbons
Gas concentration alarm level
>100 PPM
LEL alarm level
(Lower Explosive Limit)
7%
Power voltage
230V AC
Current
≤ 3W
Output voltage for the solenoid valve
9 - 12V
Sensor priming time
180 s
Sound intensity
≥ 85dB
Working temperature
-10°C ~ +50°C
Dimensions
123 x 78 x 40mm
Solenoid valve
Connection
ø3/4 inch
Input voltage
9 -12V (impulse)
Reset
Manually by lifting the red
button
Summary of Contents for Safe House Dual Gas 250LR
Page 2: ......
Page 9: ...9 3 4 inch 9 12V 100 kPa 10 C 50 C LED...
Page 10: ...10 3 4 PNI Safe House Dual Gas 250LR 0 3 1 0 m 1 5 PNI Safe House Dual Gas 250LR CO CO...
Page 11: ...11 1 1 9 12V 2...
Page 12: ...12...
Page 13: ...13 CO CO CO ppm CO 35ppm 8 CO 1600ppm CO 230V CO 100 ppm...
Page 55: ......
Page 56: ......