1 SAMPLE APPLICATION 

 

Two sample applications are included in this evaluation kit.  

 

RF test program 

 

MAC library sample program:  send and receive message. 

 
A IEEE 802.15.4 compliant MAC library is included in this evaluation kit. It 

is a linkable object-code library.  “C” source code is provided for both RF 

test program and MAC library application program.   

 
The ZM101-RS boards are pre-programmed with RF test program. All 

sample programs provide console program through the RS232 interface. A 

terminal program such as Hyperterminal is required to interact with the 

sample program and a NULL MODEM cable is needed to connect PC’s 

COM port to evaluation kit’s RS232 DB9 connector.   

 

In case no COM port is available from your PC, you can set the USB 

interface to COM port mode. Please refer to Section 3.2.4 how to setup 

jumper J1, J2, J3 for the USB COM port mode.  When USB interface to set 

to USB COM port mode, the On-Chip Debug function is disable, because it 

is the same UART interface for the debug and COM port.  To indentify USB 

COM port number, you can find it from [Control Panel] -> [System] ->  

[Hardware] -> [Device Manager] -> [Ports (COM *LTP]. Following is the 

table to setup Hyperterminal to connect to sample program’s console.  

 

 

 

 

Summary of Contents for PNI-ZM101-EV

Page 1: ...1 User Manual PNI ZM101 EV ZigBee TM ready Wireless Network Evaluation Board Using the UZ2400 RF chip And the 78K0R KE3 Microcontroller...

Page 2: ...am such as Hyperterminal is required to interact with the sample program and a NULL MODEM cable is needed to connect PC s COM port to evaluation kit s RS232 DB9 connector In case no COM port is availa...

Page 3: ...1 Flow control None Local echo Off Line feed No 1 1 RF test sample application Two PNI ZM101 EV boards are required to conduct this test J5 to J8 is used to setup the board 4 LSB address Set one unit...

Page 4: ...p back function and in the menu of the transmitter board the board with short address 0001 press 1 to setup PER test The first prompt ask you to input the destination short address you may input 0002...

Page 5: ...m 3 initiates the modulates RF transmission The data carried are pseudo random numbers 1 1 3 Continuous RX Pseudo Noise The menu item 4 initiates the carrier RF transmission 1 1 4 RX mode The menu ite...

Page 6: ...hat means 0dBm For detail of output power register please refer to UZ2400 s datasheet 1 1 10 Resetting RF The menu item A allows you to reset the UZ2400 chip registers 1 2 MAC Sample program Text Mess...

Page 7: ...7 Now you shall find the following message in the hyperterminal if not reset the evaluation board...

Page 8: ...rt the end device When successfully associated with the coordinator the end device will be assigned a short address by the coordinator and the return statur shall also be 00 Do the same step for each...