background image

 

 

 

 

PNI Sensor 

 

PlacePod User Manual V2  

Page 12 of 15 

3.5

 

INSTALL THE PLACEPOD 

PlacePod can be installed in-ground or surface-mounted, depending upon the model which was 

purchased.  Please refer to the Installation Guide for details on each type of installation.  Each PlacePod 

has a unique ID which can be found on the bottom of the sensor.  PNI recommends that you record each 

sensor ID and match it to the Parking Space ID before installing it into the parking space.  Customers 

generally want to associate a sensor with a physical location.  PNI’s Parking Application allows this 

information to be input as part of the provisioning process.  Third-party Parking Applications will also 

generally allow this, although in some systems this information is configured directly into the Network 

Service. 
Download the PlacePod Installation Guide at: 

https://www.pnicorp.com/download/placepod-installation-guide/

 

 

3.6

 

CALIBRATE THE PLACEPOD 

The PlacePod must be calibrated before it is able to properly detect vehicle parking events.  Once the 

PlacePod is installed in the parking space, ensure that the space is free of any non-permanent ferrous 

objects such as toolboxes, installation tools, and other equipment.  Also, ensure that there are no vehi-

cles in any adjacent parking spaces.  

 

Consult the 

PlacePod Vehicle Detection Sensor Utility iOS Application

 User Manual

 for detailed instruc-

tions about calibrating PlacePod. 

 

Summary of Contents for PlacePod

Page 1: ...PLACEPOD VEHICLE DETECTION SENSOR USER MANUAL...

Page 2: ...an in ground or surface mounted vehicle detection sensor that communicates with a LoRa gateway to provide real time parking data It provides accurate vehicle detection in parking spaces up to 7 years...

Page 3: ...sors and algorithms are finely tuned for ultra low power consumption providing continuous vehicle detection without missing a parking event Capability for wireless configuration and software updates u...

Page 4: ...4 NETWORK SERVICE 8 2 5 PARKING MANAGEMENT APPLICATION 8 3 PLACEPOD PARKING SOLUTION SETUP AND INSTALLATION 9 3 1 SETUP AND INSTALLATION OVERVIEW 9 3 2 SET UP OVERVIEW 9 3 3 ACTIVATE PLACEPOD 10 3 4...

Page 5: ...component of a parking management system The Sys tem Functional Elements section describes the system components and preliminary decisions that must be made to enable a smooth implementation Setup and...

Page 6: ...tion on to the Network Service The number of gateways required depends upon the size and environment of the parking areas covered by the parking system Network Service The Network Service collects the...

Page 7: ...tection sensor models 2 LoRa Communications Bandwidth The PlacePod communicates with the gateway over several LoRa bandwidths 915 MHz 868 MHz or 923 MHz The applicable bandwidth is determined by regio...

Page 8: ...slate to better coverage Deploying too few gateways will affect the network reliability due to weak signal strength at the gateways and a lack of redundancy Gateways can be ordered from many LoRa gate...

Page 9: ...n will outline the steps needed to ensure the PlacePod is successfully installed and functional This assumes that the customer has already chosen a LoRa network service provider and installed gate way...

Page 10: ...the gateway so that it has direct line of sight to the PlacePod Note For help installing gateways please contact your gateway manufacturer 3 Ensure PlacePods have been provisioned onto the LoRa netwo...

Page 11: ...er manual 3 4 INSTALLATION SITE SURVEY Once the PlacePod has been activated it is important to ensure that the sensors are able to communicate with the LoRa network by performing an installation surve...

Page 12: ...s part of the provisioning process Third party Parking Applications will also generally allow this although in some systems this information is configured directly into the Network Service Download th...

Page 13: ...e bandwidth utilized varies by region 915 MHz in North America 868 MHz in Europe PlacePod communicates with gateways using LoRa bandwidths LPWAN A Low Power Wide Area Network utilizing wireless commun...

Page 14: ...Mount 9 0 in 22 86 cm diameter 1 25 in 3 15 cm height Installation Position Center of the parking space Operating Temperature 30 C to 70 C 22 F to 158 F Storage Temperature 40 C to 85 C 40 F to 185 F...

Page 15: ...ANY OTHER LIABILITY If any Product furnished hereunder fails to conform to the above warranty Customer s sole and exclusive remedy and PNI s sole and exclusive liability will be at PNI s option to rep...