User manual
4
English
4. EXAMPLE OF INSTALLATION SCHEME:
COM
NO
+12V
- GND
A
B
C
D
A - Electric lock (PNI H1073A)
B - Access control keypad (eg. PNI DK220, PNI DK110)
C- Switching power supply (eg. PNI ST3.4A)
D - Access button (eg. PNI PB410)
NOTE:
The lock installation must be performed by specialized personnel only.
5. RECOMMENDED COPPER WIRE:
Section mm
2
Diameter Ø
Length m
0,30
0,6
8
0,5
0,8
15
1
1,2
25
1,5
1,4
40
2,5
1,8
60
6. TECHNICAL DETAILS:
Electric lock outer housing material
Steel
Cylinder and latch material
Brass
Operating voltage (only impulse)
0,5 - 3s @ 7 - 12 V d.c. / 2 - 3.5A
Lifespan
at least 200.000 actions
Recommended door thickness
35 - 50 mm
Included keys
Yes, 3 pcs.
Dimensions
125 x 101 x 39 mm
Operating temperature
-26°C ~ +80°C