![PNI DU160 User Manual Download Page 16](http://html1.mh-extra.com/html/pni/du160/du160_user-manual_1569880016.webp)
-
14
-
P18
Delay before
opening
2
1-60
1 means 0.1S
P19
Low-speed
current
80
20-150
Unit 0.01A
P22
Remote
control
mode
selection
1
1-2
1.
Inching (all keys can
be used as open key, the
door
opening
time
delay
to
automatic
closing)
2.
Interlocking (press
open key to open the
door and keep it open
normally, need to press
close key to close).
P23
Factory holds
Factory holds
P24
Selection of
Magnetic
/Electronic
Lock
1
1-2
1Magnetic lock(power on
and lock)
2 Electronic
control
lock ( (power on and
open)
P25
Factory holds
Factory holds
P26
Coefficient of
downwind
resistance
7
1-10
0
Maximum
wind
resistance
3.2.