15
Power
voltage
Unlock relay
Work ambient temperature
Storage ambient temperature
Work relative humidity
Storage relative humidity
Card memory
PIN memory
Reader frequency
Compatible card type
Card reading distance
Electric lock interface
Available connections
12Vdc+12% / 1.2A
12Vdc/2A
-10 ~ 45°C
-10 ~
5
5°C
40~90% RH
20~90% RH
1000 bc
1*public , 1000*private
125KHz
EM (electromagnetic)
0 - 5 cm
NO or NC relay output
Exit button / Bell
/ Door contact / Alarm
1. Technical specifications
2.
Factory
d
efault
v
alues
Programming PIN
Door open mode
Private PIN
Unlock time
Tamper alarm
Door contact
Lock status
Alarm delay
Modify private PIN
881122 (please change this when
first installing the keypad)
Card or PIN
(default public PIN 1234)
0000
3 sec
On
Off
Off
0 sec
Off