of the week are fixed from Monday to Sunday (1 ~ 7), each day has 4 time periods (1 ~ 4). Each press of the
P button can be performed in the next setting.
1). Press P and hold for 3 seconds, the “hour” display flashes, change the value with the + and - buttons.
2) Press the P button, the temperature blinks, change the desired temperature with the + and - buttons.
3). Press the P button for the next time.
4). Repeat the settings for the other days and periods similarly.
Period
1
2
3
4
Hour
Temp
Hour
Temp
Hour
Temp
Hour
Temp
12345 (Mon-Fri)
7:00
22
°
C
8:30
19
°
C
17:00
22
°
C
22:00
19
°
C
6 (Sat.)
8:00
22
°
C
8:30
22
°
C
17:00
22
°
C
22:00
19
°
C
7 (Sun.)
8:00
22
°
C
8:30
22
°
C
17:00
22
°
C
22:00
19
°
C
ADVANCED PARAMETER SETTINGS
Turn the thermostat screen Off by pressing the On / Off button. With screen Off, press and hold in the
same time
and
buttond for parameters settings. Pres M to navigate and arrows to change value.
Press ON/OFF button to exit menu.
MENU
Description
Range
Defalt value
01
Temp. calibration for internal sensor
-8
°
C ~ 8
°
C (0.5
°
C step)
0
°
C
02
Set Point Max.
5
°
C ~ 35
°
C
35
°
C
03
Set Point Min.
5
°
C ~ 35
°
C
5
°
C
05
Frost Protection Temp.
5
°
C ~ 15
°
C
5
°
C
09
Histerezis ( Deadzone - 0.1
°
C step)
0.2
°
C ~ 6
°
C
0
°
C(Off)
11
Child lock function
1: ON 0: Off
0
12
Open window detect function-OWD
On Off
0
13
OWD - Detect time
2 ~ 30 minutes
15 minutes
14
OWD - Drop temp. select ( within
detect time)
2,3,4
°
C
2
°
C
15
OWD - Delay time select
(Return to previous working status)
10 ~ 60 minutes
30 minutes
17
Factory reset
0 : No
0
1: Yes, and then press
On/off button for 5s,wait
until thermostat restart.
Software Version
5055-02
RECEIVER WIRING DIAGRAM
The operation of connecting the receiver unit with 230 V power supply and central heating system must be
performed only by qualified personnel and only after consulting the thermostat and boiler documentation.
The receiver unit has a relay command (NO and NC / Normal Open and Normal Closed) without potential
(non-energized/dry contact) which executes the closing of a control circuit with a maximum current of 10 A,
and a maximum voltage of 250 V AC / DC. Find examples of connection with certain models of boilers at the
end of the manual.
Summary of Contents for CT36
Page 16: ...BG 16 PNI CT36 230 VAC 2 4 GHz Wi Fi PNI CT36 Android iOS Tuya Smart Google Play App Store QR...
Page 22: ...BG 22 2 Ferroli DivaCondens 24 28 3 Vaillant Ecotec Pure 4 Motan Max Optimus 2 1...
Page 23: ...BG 23 2...
Page 31: ...DE 31 2 An der Wand mit Wandhalter...
Page 39: ...ES 39...
Page 47: ...FR 47...
Page 55: ...HU 55...
Page 77: ...PL 77...