Pneumax
PTO-Driven Compressor Kit Installation Guide
Page 12 of 36
Separator/filter installation
The separator filter can be installed anywhere there is room to securely mount it and run the
hydraulic and air lines. The only requirements are to make sure that the filter element can be
serviced reasonably and that the assembly is installed properly.
•
Install it vertically, with the housing up, the filter element down.
•
Make sure there is room to remove and replace the filter element.
Oil Scavenger
to Compressor
(behind bracket)
To Balance Valve and
Fixed/Manual Regulator
To Air
Manifold
From
Sump
Separator/filter side view with fittings
Oil Scavenger
to Compressor
From
Sump
Separator/filter and bracket detail
Summary of Contents for 140-SP
Page 28: ...PTO Driven Compressor Kit Installation Guide Page 28 of 36 Compressor Installation Angles...
Page 29: ...PTO Driven Compressor Kit Installation Guide Page 29 of 36 Eight Inch Vertical Sump...
Page 30: ...PTO Driven Compressor Kit Installation Guide Page 30 of 36 Ten Inch Vertical Sump...
Page 31: ...PTO Driven Compressor Kit Installation Guide Page 31 of 36 80 P Heat Exchanger Oil cooler...