Relieving Regulator

Adjustable

Non-Relieving Regulator

Adjustable

Pneumatic Division

Richland, Michigan 49083
269-629-5000

Installation and Service Instructions
IS-R55

R55 Series Regulator

ISSUED:  September 2005

Doc. #ISR55, ECN #050388, Rev. 1

 

WARNING

To avoid unpredictable system behavior that can cause personal injury
and property damage:

Disconnect electrical supply (when necessary) before installation,
servicing, or conversion.

Disconnect media source and depressurize all media lines
connected to this product before installation, servicing, or
conversion.

Operate within the manufacturer’s specified pressure, temperature,
and other conditions listed in these instructions.

Medium must be moisture-free if ambient temperature is below
freezing.

Service according to procedures listed in these instructions.

Installation, service, and conversion of these products must be
performed by knowledgeable personnel who understand how
pneumatic products are to be applied.

After installation, servicing, or conversion, media and electrical
supplies (when necessary) should be connected and the product
tested for proper function and leakage. If audible leakage is present,
or the product does not operate properly, do not put into use.

Warnings and specifications on the product should not be covered
by paint, etc. If masking is not possible, contact your local
representative for replacement labels.

!

     WARNING

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF
THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR
RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND
PROPERTY DAMAGE.

This document and other information from The Company, its
subsidiaries and authorized distributors provide product and/or system
options for further investigation by users having technical expertise. It
is important that you analyze all aspects of your application, including
consequences of any failure and review the information concerning
the product or systems in the current product catalog. Due to the
variety of operating conditions and applications for these products or
systems, the user, through its own analysis and testing, is solely
responsible for making the final selection of the products and systems
and assuring that all performance, safety and warning requirements of
the application are met.
The products described herein, including without limitation, product
features, specifications, designs, availability and pricing, are subject to
change by The Company and its subsidiaries at any time without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR
INCLUSION IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE
THESE PRODUCTS. CONTACT YOUR LOCAL REPRESENTATIVE.

!

Introduction

Follow these instructions when installing, operating, or servicing
the product.

Application Limits

These products are intended for use in general purpose
compressed media systems only.

Operating Pressure:

kPa

PSIG

bar

Maximum Inlet Pressure

2068

300

21.0

Ambient Temperature  Range:

4°C to 49°C

(40°F to 120°F)

Symbols

Installation

1. The regulator should be installed with reasonable

accessibility for service whenever possible - repair service
kits are available. Keep pipe and tubing lengths to a minimum
with inside clean and free of dirt and chips. Pipe joint
compound should be used sparingly and applied only to
the male pipe - never into the female port. Do not use PTFE
tape to seal pipe joints - pieces have a tendency to break
off and lodge inside unit, possibly causing malfunction.

2. Install regulator so that media flow is in the direction of

arrow. Installation must be upstream (high pressure) side
and as close to the devices it is to service (valve, cylinder,
tool, etc.). Mounting may be in any position.

3. Gauge ports are located on both sides of the regulator

body for your convenience. It is necessary to install a
gauge or pipe plugs into each port during installation.

4. For protection against rust, pipe scale, and other foreign

matter, install a filter on the upstream (high pressure) side
as close to the regulator as possible.

Reduced Pressure Adjustment

To adjust reduced pressure settings, loosen lock screw in center
of knob and turn knob clockwise to increase pressure setting,
and counterclockwise to lower setting.  With relieving-type
regulators, the reduced pressure follows adjustment of the screw.
With non-relieving regulators, adjustment for lower reduced
pressure will not be obtained until the reduced pressure system
is “bled off” or until air flow starts.

       

WARNING

Product rupture can cause serious injury.

Do not connect regulator to bottled gas.

Do not exceed maximum primary pressure rating.

!