3.
Repeat until the signal at CV OUT reaches an ATTACK PEAK of 10V and then immediately starts
to decay.
MAXIMUM SUSTAIN
1.
Turn the SUSTAIN control to MAX.
2.
Press and hold a key until it attacks, decays and then reaches the sustain level and continue
holding.
3.
Turn R30 (MAXIMUM SUSTAIN) trimmer in either direction until the voltage meaured is +10V
4.
Now when VR3 (SUSTAIN LEVEL) is set to maximum, there will be no DECAY time. You can play
with this setting if you want different behavior.
Operation
The Envelope Out jack will in general be used to control a VCA or filter in response to the ADSR curve
generated during the time that a GATE signal is applied to the GATE jack.