A function (
Ct-Hi
...
Ct-IF
) can be allocated to 4 control signals.
Function
Ct-Hi
reset max
The maximum value memory is reset to the instantaneous input
value (same function as
I
D
)
Ct-Lo
reset min
The minimum value memory is reset to the instantaneous value
(same function as
D
I
)
Ct-F2
Control signal of mathematic function 2
(reset
TArA
,
TrSt
,
IntE
or
LEAD
or switch off
LAG1
)
Ct-di
Display switch-over
Normally, the output value of mathematic function 2 is indicated.
The input value can be displayed via a control input (compare page 9)
Ct-5c
Scanner ON / OFF
The scanner can be controlled via a control input. As soon as
Ct-Sc
not equal 0, setting
SC_on
/
SC_OF
(
Ä
page 16) is without
effect!
Ct-IF
local / remote
local
:
Front panel operation. Via interface , values can be measured but
not changed.
remote
:
Operation via interface. Simultaneously, changing values via the
keyboard is prevented.
The following adjustments are possible:
Value for
Ct-Hi
...
Ct-IF
Control signal
no
no control signal
d1
control input
d1
r
page 3
d2
control input
d2
r
page 3
Front
F
key
IF
interface
(
not
possible with
Ct-di
and
Ct-IF
)
+
In the automatic scanner mode (green LED at channel
selector), the control inputs act on all channels.
In the manual mode, the control inputs act only on the
actual channel!
9499-040-24701