000115682/151018/0 WallPro
EN - 16
Component Action
Frequency:
every X months
X=6
X =12
Filter unit
Dustbin
Empty; refer to paragraph 6.3
*)
Housing
Clean the outside with a
non-aggressive detergent
X
Clean the inside with an industrial
vacuum cleaner and remove dust
from the filter compartment
X
Check sealing material of the
door. Replace if necessary
X
Mains cord
Check for damage. Repair or
replace if necessary
X *)
Extraction fan
Fan housing
Check for encrusted particles.
Clean if necessary
X
Extraction arm
Tubes
Clean the outside with a
non-aggressive detergent
X
Clean the inside thoroughly
X
Flexible
hoses
Check for cracks or damages.
Replace if necessary
X
Hood
Check the movement of the hood.
If necessary, adjust the friction;
refer to paragraph 6.4
X
Arm
movement
Check horizontal, vertical and
diagonal arm movement. If
necessary, adjust the friction;
refer to paragraph 6.4
X
*) During use, you must check the level of contents in the dustbin
regularly. The emptying frequency depends on the intensity of use and
will be a matter of experience. In the initial stage, do a check on the
level of contents of the dustbin 2 times per month.
6.2
Filter replacement
When the red LED (FILTER CLOGGED) is on, you must replace
the filter cartridge.
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you replace the filter
cartridge.
WARNING
Do not replace the filter cartridge while the fan is
running.
To replace the filter cartridge, do the following.
Scan the QR code to watch a short
demo about filter replacement.
• De-energize the unit.
• Turn the rotary knob (A) in horizontal position to close the
shut-off valve.
• Loosen the quick release clamp (F) and remove the dustbin
(G).
• Loosen the duct clamp (D) and remove the flange (E).
If there is enough space behind the filter unit to
turn the hopper including flange 90°, it is not
necessary to remove the flange.
• Loosen the 2 wing knobs (C) and release the bag frame
(B).
Fig. 6.1
A
B
D
C (2x)
E
F
G
Bag frame
• (1) Put a plastic bag from the inside through the bag
frame.
• (2) Close the bag frame and (3) fasten it with the 2 wing
knobs.
Fig. 6.2
2
1
3
Plastic bag
To guarantee dust-free filter removal, you must loosen the star
knobs of the hopper and the filter cartridge via the outside of
the plastic bag. This means that you do not touch the knobs
directly.
• Loosen the 2 star knobs (D) and release the hopper (C).
• Move the hopper in fully vertical position. Lock the hopper
with the lid stays (B).
• Loosen the star knob (A) and carefully lower the filter
cartridge into the plastic bag.
• Lift the plastic bag, turn it around and seal it with a cable
tie.