• Put adhesive rubber strip (G) around the opening of the
arm bracket. Make sure that the strip does not entirely
cover the holes.
• Put the mounting flange (D) over the duct flange (C).
• Put the bend (E) into the duct flange (C).
• Put the other side of the bend (E) into the inlet flange
26
(B).
• Install the mounting flange to the arm bracket with 4x
bolts M8 with 8x washers and 4x locknuts (F), that are
supplied with the extraction arm.
• Make sure that all connections are airtight.
Fig. 4.14
4x
B
C
A
EM
D
E
F
G
Inlet ducting
In case of:
EM
• If applicable
27
: install the duct adapter metric-imperial (A)
in the inlet flange (B).
• Install ducting
28
between B (or A) and the extraction arm.
• Make sure that all connections are airtight.
4.8
Dustbin
To install the dustbin, do the following.
• Install the dustbin assembly (C) to the hopper (A) with the
supplied duct clamp (B).
• Turn the rotary knob (D) in vertical position to open the
shut-off valve.
A
C
B
D
Fig. 4.15 Mounting of the dustbin
26. Inlet non-return valve (assembly)
27. In case of 60Hz configurations with an imperial duct size (Ø 6 in. or Ø 8 in.)
28. Ø 160 mm / 6 in. or Ø 200 mm / 8 in., depending on the inlet diameter
4.8.1 Dustbin extension set (option)
For easy maintenance, you can install the dustbin on the floor
via the dustbin extension set.
The dustbin extension set consists of the following
components:
A Duct connection ring
B Extension duct Ø 200 mm / Ø 8 in. (to be sourced locally)
C Hose clamp
D Rubber collar
E PVC hose
F Hose clamp
G Rubber collar
H Hose connection ring
I Duct clamp
Fig. 4.10
A
B
C
D
E
F
G
H
I
Dustbin extension set
• Install the dustbin extension set between the filter unit and
the dustbin with the supplied comp extension
duct.
• Use the rubber collars to make the connections airtight.
4.9
Control box
4.9.1 Connections
Refer to the separately supplied electrical diagram
for the electric connections. Refer to paragraph
4.1.1 for the required cable specifications.
In case of:
UL
Components necessary for electrical installation
according to UL and federal, state or local wiring
regulations are not included and must be sourced
locally.
• Install the control box at an appropriate position.
• Connect the control box to the fan (B).
• Connect the control cable (C) from the filter unit to the
control box (refer to Fig. 4.9E).