Plymovent SPARKSHIELD Installation And User Manual Download Page 3

0507061510/010921/C SparkShield 

2

PREFACE

Using this manual

This manual is intended to be used as a work of reference for 

professional, well trained and authorised users to be able to 

safely install, use, maintain and repair the product mentioned 

on the cover of this document.

Pictograms and symbols

The following pictograms and symbols are used in this manual:

TIP

Suggestions and recommendations to simplify 

carrying out tasks and actions.

ATTENTION

A remark with additional information for the user. A 

remark brings possible problems to the user’s 

attention.

CAUTION!

Procedures, if not carried out with the necessary 

caution, could damage the product, the workshop or 

the environment. 

WARNING!

Procedures which, if not carried out with the 

necessary caution, may damage the product or 

cause serious personal injury. 

WARNING!

Fire hazard! Important warning to prevent fire. 

Personal protective equipment (PPE)

Instruction to use respiratory protection when you 

do service, maintenance and repair jobs. We 

recommend to use a half-face respirator according 

to EN 149:2001 + A1:2009, classe FFP3 (Directive 

89/686/EEC).

Personal protective equipment (PPE)

Instruction to use protective gloves when you do 

service, maintenance and repair jobs.

Text indicators

Listings indicated by “-” (hyphen) concern enumerations.

Listings indicated by “•” (bullet point) describe steps to 

perform. 

Service and technical support

For information about specific adjustments, maintenance or 

repair jobs which are not dealt with in this manual, please 

contact the supplier of the product. He will always be willing to 

help you. Make sure you have the following specifications at 

hand:

 

- product name

 

- serial number

INTRODUCTION

1.1 

General description

The SparkShield is a cyclonic spark arrester that is highly 

effective on sparks and cigarette butts. Besides, it is a very 

effective in-line pre separator to reduce dust load in the 

connected filter system.

For an effective removal of cigarette butts, we 

recommend an air velocity in the connected duct of 

min. 11 m/s.

1.2 

Product combinations

The SparkShield is part of Plymovent’s SHIELD fire 

safety solutions for prevention, detection and 

suppression of fire.

You can also use the SparkShield as separate spark arrester in 

the extraction duct of central filter systems.

Refer to the available application data sheet for 

possible product combinations.

1.3 

Options and accessories

The following products are available as an option and/or 

accessory:

General:

Inspection hatch IH-200/8

Ø 200 mm / 8 in.

Shut-off valve:

 

- MD-200

Ø 200 mm

 

- MD-8

Ø 8 in.

 

- EFC

Industrial detergent

SparkShield-250 | 10:

 

- Inspection hatch IH-250/10 (2x) Ø 250 mm / 10 in.

SparkShield-400 | 16:

 

- Inspection hatch IH-400/16 (2x) Ø 400 mm / 16 in.

SparkShield-500 | 20:

 

- Inspection hatch IH-500/20 (2x) Ø 500 mm / 20 in.

SparkShield-630 | 24:

 

- Inspection hatch IH-630/24 (2x) Ø 630 mm / 24 in.

1.4 

Technical specifications

Material:

 

- housing (inlet + outlet)

powder-coated steel

 

- cyclone SparkTwist

galvanized steel

 

- dustbin

tin

 

- hose

spark resistant 

glassfibre/kevlar/metal

Weight (excl. dustbin):

 

- SparkShield-250 | 10

25 kg (55 lbs.)

 

- SparkShield-400 | 16

46 kg (101 lbs.)

 

- SparkShield-500 | 20

52 kg (115 lbs.)

 

- SparkShield-630 | 24

118 kg (260 lbs.)

Volume of dustbin

13 litres (± ½ CF)

25 litres (± ⅞ CF)

1.5 

Dimensions

Refer to Fig. I on page 8.

Summary of Contents for SPARKSHIELD

Page 1: ...www plymovent com Cyclonic spark arrester SPARKSHIELD Installation and user manual EN...

Page 2: ...e and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given on the cover page Thus the manufacturer...

Page 3: ...the supplier of the product He will always be willing to help you Make sure you have the following specifications at hand product name serial number 1 INTRODUCTION 1 1 General description The SparkShi...

Page 4: ...F G H A B C D E F G H Fig 2 1 Main components 2 2 Operation The SparkShield consists of a horizontally mounted in line spark arrester with dustbin underneath Due to their weight sparks and other debr...

Page 5: ...d by the manufacturer inclusive of his directions in the sales brochure In case of doubt it is the use which can be deduced from the construction the model and the function of the technical product wh...

Page 6: ...min 6 Duct imperial size inch Place a reducer metric imperial 10 16 20 24 in A in both duct ends and fasten them with self tapping screws min 6 Lift the spark arrester C in line with the duct and moun...

Page 7: ...ied with the inspection hatches Insert the hatches in the cut outs Turn the handles 90 to fasten them and make the ducts airtight Refer to the mounting instruction supplied with the inspection hatches...

Page 8: ...cover is provided with a flexible hose to facilitate replacement of the dustbin To replace the dustbin do the following Turn off the connected extraction fan Without shut off valve Loosen the quick co...

Page 9: ...13 1 1 1 12 1 1 1 11 1 10 1 9 1 D B G B A C E F B G H D B A C E F SparkShield 250 10 400 16 500 20 630 24 mm inch mm inch mm inch mm inch A 500 19 710 28 900 35 1125 44 B 250 9 400 15 500 19 630 24 C...

Page 10: ...000 10000 11000 12000 13000 14000 16000 18000 20000 22000 Airflow m h 200 400 600 800 1000 1200 1400 Pressure drop Pa Pressure drop in WG 1 2 3 4 5 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 550...

Page 11: ...10 5 0000103074 SparkTwist 0000103081 0000103082 0000103083 0000103084 0690020040 0690020050 Article no Description 9824000300 DB 13 Dustbin 13 litres 9824000310 DB 13 Dustbin 13 litres 5 pcs 98240004...

Page 12: ...www plymovent com 0507061510 010921 C SparkShield...