Plymovent PCU-1000 Installation And User Manual Download Page 4

0000101010/141119/2 PCU-1000/7500  

EN - 3

PREFACE

Using this manual

Pictograms and symbols

The following pictograms and symbols are used in this manual:

TIP

Suggestions and recommendations to simplify

carrying out tasks and actions

ATTENTION

A remark with additional information for the user. A

remark brings possible problems to the user’s

attention. 

CAUTION!

Procedures, if not carried out with the necessary

caution, could damage the product, the workshop or

the environment.

CAUTION

Denotes risk of electric shock.

WARNING!

Fire hazard! Important warning to prevent fire.

WARNING!

Explosion hazard! Important warning to prevent 

explosions. 

Personal protective equipment (PPE)

Instruction to use respiratory protection when you 

do service, maintenance and repair jobs, as well as 

during functional testing. We recommend to use a 

half-face respirator according to DIN EN 141/143, 

protection class P3.

Personal protective equipment (PPE)

Instruction to use protective gloves when you do 

service, maintenance and repair jobs.   

Text indicators

Listings indicated by “-” (hyphen) concern enumerations. 

Listings indicated by “•” (bullet point) describe steps to 

perform. 

Service and technical support

For information about specific adjustments, maintenance or

repair jobs which are not dealt with in this manual, please

contact the supplier of the product. He will always be willing to

help you. Make sure you have the following specifications at

hand:

- product name

- serial number

You can find these data on the identification plate.

 

Product indications

Unless specifically stated, the contents of this manual applies

to the PCU-1000/7500.

INTRODUCTION 

1.1 

Identification of the product 

The identification plate contains, among other things, the

following data:

 

- product name

 

- serial number

 

- supply voltage and frequency

1.2 

General description

PCU-1000/7500 is an energy saving control unit, which 

together with pressure sensor PC-500, makes a fully automatic 

system for the control of a vehicle exhaust fan.

ATTENTION

The control unit, PCU-1000/7500, is delivered 

without cable for supply connection, PC-500 and 

motor overload. The control unit must be provided 

with relevant motor overload for the exhaust fan.

1.3 

Technical specifications

PCU-1000

Supply 

AC-3 alternative AC-1
Internal supply 

voltage 

24 AC Secondary

External supply 

voltage 

120V, 208V, 230V, 

380V, 460V, 575V

Power consumption

max. 75 W

Input

PC-500 or similar potential free switch

Outputs 

Fan motor AC-3 alternative AC-1 
Relay exit: normally open 
Relay exit: normally closed 

Note

: Relay exits may for example be 

used at external supervision alarm 

controls 

Operating 

Automatic

Fully automatic 

start/stop of the 

exhaust fan by 

PC-500

Manual

Continuously 

running the 

exhaust fan 

Stop

Manual stop of the 

exhaust fan

Max. power

≤ 5.5 kW @ 400 V

Stop delay timer 

range

7 seconds - 6 minutes 

PCU-7500

Supply 

AC-3 alternative AC-1
Internal supply 

voltage 

24 AC Secondary

External supply 

voltage 

120V, 208V, 230V, 

380V, 460V, 575V

Power consumption

max. 75 W

Input

PC-500 or similar potential free switch

Outputs 

Fan motor AC-3 alternative AC-1 
Relay exit: normally open 
Relay exit: normally closed 

Note

: Relay exits may for example be 

used at external supervision alarm 

controls 

Summary of Contents for PCU-1000

Page 1: ...www plymovent com EN Installation and user manual PCU 1000 7500 ...

Page 2: ...page of this document This publication is to be used for the standard model of the product of the type given on the cover page Thus the manufacturer cannot be held responsible for any damage resulting from the application of this publication to the version actually delivered to you This publication has been written with great care However the manufacturer cannot be held responsible either for any ...

Page 3: ... PCU 1000 7500 2 ENGLISH Page Preface 3 1 Introduction 3 2 Product description 4 3 Safety instructions 4 4 Installation 5 5 Maintenance 5 6 Troubleshooting 5 7 Spare parts 5 8 Disposal 5 CE declaration 6 TABLE OF CONTENTS ...

Page 4: ...plate Product indications Unless specifically stated the contents of this manual applies to the PCU 1000 7500 1 INTRODUCTION 1 1 Identification of the product The identification plate contains among other things the following data product name serial number supply voltage and frequency 1 2 General description PCU 1000 7500 is an energy saving control unit which together with pressure sensor PC 500...

Page 5: ...ontrol unit is in on position the exhaust fan runs continuously The control unit also has a position for manual stop see Fig 2 1 C of the exhaust fan Observe that when the control unit and the fan are stopped manually or automatically stop delay time is out and the motor is still running there is a risk of exhaust gas leakage from the system and a risk that the exhaust hose melts due to the temper...

Page 6: ...n the vicinity of the product contains sufficient approved fire extinguishers suitable for fire classes ABC Service maintenance and repairs Obey the maintenance intervals given in this manual Overdue maintenance can lead to high costs for repair and revisions and can render the guarantee null and void Always use Personal Protective Equipment PPE to avoid injury This also applies for persons who en...

Page 7: ... of in accordance with federal state or local regulations 2 1 5 3 4 CE DECLARATION CE declaration of conformity for machinery We Plymovent Industrial Solutions B V Koraalstraat 9 1812 RK Alkmaar the Netherlands herewith declare on our own responsibility that the product s PCU 1000 7500 which this declaration refers to is in accordance with the conditions of the following Directives 2014 30 EU EMC ...

Page 8: ...www plymovent com 0000101010 141119 2 PCU 1000 7500 ...

Reviews: