![Plymovent MobilegoPlus Installation And User Manual Download Page 7](http://html1.mh-extra.com/html/plymovent/mobilegoplus/mobilegoplus_installation-and-user-manual_1569254007.webp)
0000111659/140921/C MobileGo
6
Fig. 4.3
C
A
B
F
G
H
D (2x)
E (2x)
D (2x)
Hood mounting (hose tube arm)
Fig. 4.4
C
A
F
H
G
D (2x)
D (2x)
E (2x)
Hood mounting (metal tube arm)
5
USE
WARNING!
Fire hazard! Do
not
use the product for polishing
applications in combination with grinding, welding or
any other application that generate sparks.
Refer to chapter 3 / Safety instructions / Use.
5.1
Control panel
The unit contains the following controls and indicators:
A Tumbler switch 0-1 with green LED
B Buzzer (service indicator)
Fig. 5.1
A
B
Controls and indicators
5.2
Use
Since it concerns a mobile unit, you can use it at any desirable
place. For optimal results you must place the unit as close as
possible to the source of pollution.
• Position the hood of the connected extraction arm at max.
480 mm (19 in.) from the source of pollution. Refer to Fig.
III on page 11 for the correct position.
•
Make sure that the shut-off damper (ref. Fig. 2.1A) is open.
• Put the unit on (ref. Fig. 5.1A).
• Start welding.
• When the welding position changes, move the hood to the
correct position in relation to the weld.
WARNING
To keep the welding fume away from the breathing
zone of the welder, make sure that all fume is
extracted through the hood.
•
Put the unit off approx. 20 seconds after you have finished
welding.
When the airflow is too low during use, the buzzer (ref. Fig.
5.1B) emits an acoustic alarm. Refer to chapter 7 to find the
possible cause and the solution.
ATTENTION
If you do not replace the pre filter and/or the HEPA
filter cassette in time, the airflow (extraction
capacity) further drops.
6
MAINTENANCE
6.1
Periodic maintenance
The product has been designed to function without
problems for a long time with a minimum of
maintenance. In order to guarantee this some simple, regular
maintenance and cleaning activities are required which are
described in this chapter. If you observe the necessary caution
and carry out the maintenance at regular intervals, any
problems occurring will be detected and corrected before they
lead to a total breakdown.
WARNING
Overdue maintenance can cause fire.
The indicated maintenance intervals can vary depending on
the specific working and ambient conditions. Therefore we
recommend to thoroughly inspect the complete product once
every year beside the indicated periodic maintenance. For this
purpose contact your supplier.