0000110292/010123/B MiniMan-100 | MiniMan-100 ATEX | MiniMan-100 TopGrade
2
PREFACE
Using this manual
This manual is intended to be used as a work of reference for
professional, well trained and authorised users to be able to
safely install, use, maintain and repair the product mentioned
on the cover of this document.
Pictograms and symbols
The following pictograms and symbols are used in this manual:
TIP
Suggestions and recommendations to simplify
carrying out tasks and actions.
ATTENTION
A remark with additional information for the user. A
remark brings possible problems to the user’s
attention.
CAUTION!
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop or
the environment.
WARNING!
Procedures which, if not carried out with the
necessary caution, may damage the product or
cause serious personal injury.
WARNING!
Fire hazard! Important warning to prevent fire.
WARNING!
Explosion hazard! Important warning to prevent
explosions.
Personal protective equipment (PPE)
Instruction to use respiratory protection when you
do service, maintenance and repair jobs, as well as
during functional testing. We recommend to use a
half-face respirator according to EN 149:2001 +
A1:2009, class FFP3 (Directive 89/686/EEC).
Personal protective equipment (PPE)
Instruction to use protective gloves when you do
service, maintenance and repair jobs.
Text indicators
Listings indicated by “-” (hyphen) concern enumerations.
Listings indicated by “•” (bullet point) describe steps to
perform.
1
INTRODUCTION
1.1
Identification of the product
The identification plate contains, among other things, the
following data:
- product name
- serial number
1.2
General description
The MiniMan-100 is a compact flexible arm, which is ideal for
all types of smaller dust and fume applications.
The arm is fitted with exterior friction joints (“ClearThru”
design), which allows for maximum air velocity, low pressure
drop and low noise level. The inner tubes are kept in place by
a gas spring (standing arm) or a balancing strap (hanging
arm). This design ensures smooth movement of the arm.
The MiniMan-100
arm is available in four different types:
- type
H
: for hanging mounting
- type
S
: for standing mounting
- type
TopGrade
: white arm (hanging or standing), especially
suitable for use in clean working environments, such as
laboratories
- type
ATEX
: approved for use in explosive environments zone
1 and 21; marking Ex II 2G 2D (for hanging mounting only)
1
1.3
Options and accessories
DAMPER-100
Sealed shut-off valve
MiniMan-100 all types (except for ATEX versions)
S-100
manual on/off switch for hood mounting
LL-5.5/24-100
+ TR-24
manual on/off switch, incl. working light;
transformer 230/24V
1.4
Product combinations
You can use the MiniMan-100 with the following products:
Extraction fan
Suitable for
- FUA-2100 | 0,75 kW (1 HP)
- FUA-3000 | 1,1 kW (1½ HP)
- FUA-4700 | 2,2 kW (3 HP)
- 2-3 MiniMan arms
- 3-4 MiniMan arms
- 4-5 MiniMan arms
Stanchion
-
PA-110/160 | 1,1 m (3⅝ ft)
- PA-220-160 | 2,2 m (7¼ ft)
1.5
Technical specifications
Physical dimensions and properties
Length (nom.):
- MM-100-1.5
- MM-100-2.1
- 1,5 m (5 ft.)
- 2,1 m (7 ft.)
Diameter
Ø 100 mm (4 in.)
Material of tubes
aluminium
Material of hoses:
- type
H
,
S
,
Topgrade
- PVC with internal steel spiral;
flame-retardant
- type
ATEX
- PVC with internal steel spiral;
flame-retardant and antistatic
Weight (net):
- MM-100-1.5
- MM-100-2.1
- 9,5 kg (21 lbs.)
- 12 kg (26½ lbs.)
Arm rotation:
- type
H
,
S
,
Topgrade
- type
ATEX
- 360°
- max. 359° (due to the litz
wire)
Performance
Recommended airflow
-
min. airflow
200-450 m
3
/h (118-265 CFM)
- 200 m
3
/h (118 CFM)
1.6
Working reach
1.7
Pressure drop
Refer to the available product data sheet for
detailed product specifications.
1. In accordance with TRGS 727 & ATEX Directive 2014/34/EU