background image

0000100513/050719/C MDB GO | MDB PRO 

12

Fig. 4.27 

2

1

3

4

Cover plates

4.8 

Filter cartridges

To install the filter cartridges, do the following. 

Fig. 4.28

•  Loosen the star knob (F) and disassemble the cover plate 

(E), the nut (D) and the metal washer (C).

•  Put the filter cartridge (B) on the cartridge holder (A). 
•  Install the removed parts in reverse order. 

Fig. 4.28 

A

B

D

C

E

F

Installation of the filter cartridges

ATTENTION

Make sure that the front of the filter cartridge 

aligns

*)

 with the filter housing, so that the lid closes 

well. If this is not the case, the filter cartridge is not 

positioned correctly. This can cause leakage and less 

efficient operation of the filter cartridge. 

*)

 tolerance: max. 2 mm (0.1 in.)

>2 mm

 max. 2 mm

>2 mm

 max. 2 mm

>2 mm

 max. 2 mm

>2 mm

 max. 2 mm

•  Do the same procedure for the remaining filter 

cartridge(s). 

4.9 

Dustbin

Fig. 4.29

•  Put the dustbin (D) below the hopper (A).  
•  Use the handle (C) to lift the dustbin and put it in the right 

position.

•  Attach the dustbin to the hopper with the quick connect 

clamp (B). 

Fig. 4.29 

A

B

C

D

 Dustbin

4.10 

Electric connection

For the electric connection of the filter cleaning 

system and the fan, refer to the installation manual 

of the control equipment ControlGo or ControlPro, 

that is supplied with the product.

4.11  Options

4.11.1  Balancing damper MRD-315/400/500

•  Install the damper at an appropriate position in the inlet 

duct.  

4.11.2  PRECO-N (precoat material)

Personal protective equipment (PPE)

Wear respiratory protection and protective 

gloves when you apply precoat material.  

•  Disconnect the compressed air supply.

•  Put the precoat material in a bucket.

•  Remove the dustbin.

•  Start the connected fan. It must run at full speed.

•  Gradually

11

 add the precoat material into the hopper.

•  Stop the fan.

•  Install the dustbin.

4.12  Installation checklist



#

Check

OK

1.

Have you tightened all bolts of the mounting frame?

2.

Are all connections airtight? 

3.

Is 4-5 bar of compressed air available?

4.

Are the filter cartridges installed in the right way?

5.

Is the dustbin correctly installed? Is it attached to the 

hopper with the quick connect clamp?

11.

  Dosing speed: approx. 1 kg (2.2 lbs.) per minute

Summary of Contents for MDB GO

Page 1: ...www plymovent com Central filter system modular MDB GO MDB PRO Installation and user manual EN...

Page 2: ...uideline for installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given...

Page 3: ...iDust Bank equals to MDB The specific product type 4 6 8 etc corresponds with the number of filter cartridges Suffixes H horizontal layout V vertical layout no suffix square layout 1 INTRODUCTION 1 1...

Page 4: ...to ISO 8573 3 class 6 Required pressure 4 5 bar 60 75 PSI Compressed air connection push in fitting in in out 12 mm Compressed air consumption 40 50 nl pulse 1 4 1 8 ft pulse Electrical data Input vol...

Page 5: ...uctions and directions given Do not change the order of the steps to perform Always keep the manual with the product Pictograms and instructions on the product if present The pictograms warning and in...

Page 6: ...s for persons who enter the work area Check the working environment Do not allow unauthorised persons to enter the working environment Protect the product against water and humidity Make sure the room...

Page 7: ...V on page 18 B Air outlet module MDB OUTLET Fig 4 4 Drill a 9 mm 0 25 in hole in the two notches A of the outlet module Fig 4 2 A 2x Air outlet module 2 Note the open sides of the bars are on the outs...

Page 8: ...g the sticky side with your fingers Make sure that you attach the seal in the centre of the frame edges and that the jigsaws fit together Peel approx 50 mm of the backing material A and stick the seal...

Page 9: ...rry about a slight misalignment of the seal holes Fig 4 14 Start with a long seal 1046 mm Try to avoid touching the sticky side with your fingers Make sure that you attach the seal in the centre of th...

Page 10: ...e Fig 4 16 Put the MDB FRAME A in fully horizontal position 8 The seals are extremely adhesive without the use of SealApplicator components might stick together in the wrong position and cannot be dis...

Page 11: ...lter modules and tighten them with a flange nut B Fig 4 22 A A A A B B B B B A 4x B 5x Position of studs Fig 4 23 Multiple stack MDB system only 1 Remove the backing material of the seals horizontal v...

Page 12: ...an end cap When you install ducting at both sides of the modules you do not need to install an end cap If applicable Put an end cap on the open side of the air inlet outlet module Fasten it with self...

Page 13: ...hopper with the quick connect clamp B Fig 4 29 A B C D Dustbin 4 10 Electric connection For the electric connection of the filter cleaning system and the fan refer to the installation manual of the c...

Page 14: ...s in the dustbin regularly The emptying frequency depends on the intensity of use and will be a matter of experience In the initial stage do a check on the level of contents of the dust drawer two tim...

Page 15: ...cartridges Inverted direction of rotation of the motor of the connected fan Change the direction of rotation Pollution of the facility Filter cartridge s ripped or placed incorrectly Replace the filt...

Page 16: ...s of the following Directives Machine Directive 2006 42 EC EMC 2014 30 EU LVD 2014 35 EU ErP Directive 2009 125 EC Alkmaar Netherlands 1 July 2019 M S J Ligthart Product Manager An installation is def...

Page 17: ...51 5 5 15 7 5 20 PTFE 15 180 1938 5400 14400 3178 8476 MDB 16 16 PTFE 10 160 1722 4800 12800 2825 7534 5 5 18 5 7 5 25 PTFE 15 240 2583 7200 19200 4238 11301 MDB 18 18 PTFE 10 180 1938 5400 14400 3178...

Page 18: ...4x 18x 2x 22x 26x 22x 11x MDB COVER 2 4x 18x 2x 22x 26x 22x 11x MDB COVER U 4x 18x 2x 22x 26x 22x 11x MDB INLET 315 MDB INLET 400 MDB INLET 500 4x 18x 2x 22x 26x 22x 11x MDB OUTLET 315 MDB OUTLET 400...

Page 19: ...uence of MDB system if applicable install the MDB BM 2 module s first layer by layer from left to right one filter module at a time 1 2 3 1 2 3 4 5 6 1 2 3 2 4 6 Fig V Inlet and outlet positions Possi...

Page 20: ...lve inch 0000102584 Lock kit for CART filter cartridge 0000102598 Star knob M12 0000102666 Cover plate for filter cartridge CART 0000102675 Filter cartridge holder Article no Description 0000103150 Ma...

Page 21: ...www plymovent com 0000100513 050719 C MDB GO MDB PRO...

Reviews: