0000111691/011121/B MonoGo 

5

ATTENTION

Before you carry out service, maintenance and/or 

repair jobs:

 

- fully disconnect the unit from the mains

Personal protective equipment (PPE)

Wear respiratory protection and protective 

gloves during service, maintenance and 

repairs.

WARNING

The industrial vacuum cleaner that you use during 

service and maintenance must meet dust class H 

according to EN 60335-2-69 or HEPA class 

(efficiency ≥99.97% at 0.3 µm).

INSTALLATION

4.1 

Tools and requirements

You need the following tools and requirements to 

install the unit:

 

-

basic tools

 

-

fork-lift truck

4.1.1 

To be sourced locally

 

- wall mounting hardware

4

 

-

mains cord 3G1.5 (3x1,5 mm²)

 

-

cable gland M20

 

-

option: plug

5

4.2 

Unpacking

Make sure that the product is complete. The 

package contains: 

Filter unit

 

-

stationary filter unit, incl. wall bracket

 

-

bolt M10x30 (2) + locknut M10 (2) + washer (4)

 

-

washer M6 (8)

 

-

bolt M6x25 (8)

Extraction arm

In case of MonoGo: hose tube arm

 

-

extraction arm (pre-assembled; excl. hose tube)

 

-

hose tube

 

-

hose clamp (2)

 

-

rotating flange

 

-

arm swivel ring, incl. rubber collar

 

- extraction hood

 

- hood collar with safety mesh

 

- washer M20

 

-

hexagon bolt M6x25 (4)

In case of MonoGo

plus

: metal tube arm

 

-

extraction arm (pre-assembled)

 

-

rotating flange

 

-

arm swivel ring, incl. rubber collar

 

- extraction hood

 

- hood collar with safety mesh

 

- washer M20

 

-

hexagon bolt M6x25 (4)

Control equipment

 

-

switch box

4.  The type of hardware depends on the wall type
5.

  Alternative: direct connection to the mains + additional main switch

4.3 

Stationary filter unit

ATTENTION!

Before you install the unit, make sure that the wall 

is strong enough. Refer to paragraph 1.4 for the 

weight of the unit.

• 

Refer to Fig. III on page 10 for the recommended 

installation height and the hole pattern of the wall bracket.

To install the wall bracket, do the following.

Fig. 4.1

•  The wall bracket is temporarily attached to the unit by a 

cable tie. Cut the cable tie.

•  Install the wall bracket (B) to the wall. Use all 4 mounting 

points.

•  Lift the unit and insert the hooks (A) in the slots of the wall 

bracket.

•  Attach the unit to the wall bracket with the bolts, locknuts 

and washers (C).

Fig. 4.1 

B

A

C

Mounting of the wall bracket

4.4 

Arm on stationary unit

To install the extraction arm, do the following.

TIP

Do a balance check of the arm before you fasten the 

hoses. Refer to paragraph 6.3.

Fig. 4.2

•  Remove the locknut M20 (A) from the hinge rod (E).
•  In case of a hose tube arm: put the hose tube over the 

internal rods of the arm.

•  Move the hose clamp (F) and the arm swivel ring (incl. 

rubber collar) (D) over the hinge rod (E).

•  Put the washer M20 (C) on the arm swivel ring (D).
•  Put the hinge rod (E) in the rotating flange (B).
•  Put the hose (G) over the arm swivel ring (D).
•  Use the rubber collar to make the connection airtight.
•  Attach the hose (G) to the swivel ring (D) with the hose 

clamp (F).

•  Put the locknut M20 (A) on the hinge rod (E) and tighten it.
•  Install the assembly to the filter unit with the 8 bolts 

M6x25 + washers M6.

Summary of Contents for DUALGO

Page 1: ...www plymovent com Stationary welding fume extractor with flexible arm MONOGO MONOGOPLUS Installation and user manual EN...

Page 2: ...and is therefore subject at any time to change or amendment and the right to change or amend is hereby expressly reserved The instructions in this publication only serve as a guideline for installati...

Page 3: ...ing specifications at hand product name serial number You can find these data on the identification plate Product indications Unless specifically stated the contents of this manual applies to the Mono...

Page 4: ...elements 2 2 Operation The MonoGo works in accordance with the recirculation principle Welding fume is extracted through the hood of the connected extraction arm by the built in fan The polluted air p...

Page 5: ...product is suited as specified by the manufacturer inclusive of his directions in the sales brochure In case of doubt it is the use which can be deduced from the construction the model and the functio...

Page 6: ...4 The type of hardware depends on the wall type 5 Alternative direct connection to the mains additional main switch 4 3 Stationary filter unit ATTENTION Before you install the unit make sure that the...

Page 7: ...tube arm 4 6 Switch box Install the switch box at an appropriate position Connect the switch box to the filter unit and to the mains in accordance with the separately supplied electrical diagram 5 USE...

Page 8: ...X Check sealing material of the door Replace if necessary X Extraction fan Check for encrusted particles Clean if necessary X Mains cord Check for damage Repair or replace if necessary X Extraction a...

Page 9: ...sition Adjust the friction refer to Fig VI on page 12 for the adjustment points 6 3 2 Metal tube arm KUA Determine which joint needs more or less friction Loosen the hose at that position to get acces...

Page 10: ...DISPOSAL Dismantling and disposal of the unit must be done by qualified persons Personal protective equipment PPE Wear respiratory protection and protective gloves when you dismantle and dispose of t...

Page 11: ...3 3 3 4 4 4 m ft ft m 0 0 2 2 4 4 6 6 8 8 10 10 12 14 12 14 0 2 4 6 8 10 12 14 0 1 1 1 2 2 2 3 3 3 4 4 4 m ft ft m A A B B C C A A B B C C A EA 2 H KUA 160 2H B EA 3 H KUA 160 3H C EA 4 H KUA 160 4H...

Page 12: ...0000111691 011121 B MonoGo 11 ANNEX Fig V Reset button A B C 0 1...

Page 13: ...0000111691 011121 B MonoGo 12 ANNEX Fig VI Adjustment of the extraction arm Adjustment points 17 17 17 10 10 17 6 6 C A F H G D 2x D 2x E 2x...

Page 14: ...ANNEX Fig VII Exploded view MonoGo MonoGoplus 0000100583 0000117142 0000111637 0000111628 0000111636 0000117141 0000117114 0000117117 0000117118 0000117128 0000117129 0000117135 0000117136 0000117904...

Page 15: ...r cassette 15 m 0000117114 Buzzer 230V 0000117118 Service indicator green 230VAC 0000117121 Pressure switch CE 0000117129 Circuit breaker ST 1 10A 0000117136 Motor 1 1 kW 230V 1ph 50Hz IEC 0000117142...

Page 16: ...ANNEX Fig VIII Exploded view hose tube arm Economy Arm 0000101937 0000101550 0000101912 2x 0000101912 0000101917 0000101918 0000101919 0000101908 0000101537 0000102989 0000101395 0000101903 0000101944...

Page 17: ...washer 0000101908 Hood collar incl handle damper and hood hinge 0000101911 Hood hinge incl mounting material 0000101912 Friction plate 83x10x3 mm set of 2 0000101937 Safety mesh 300 mm 0000101944 Con...

Page 18: ...37 0000101550 0000101906 0000101915 0000101904 0000101905 0000101913 0000101914 0000101908 0000101537 0000102989 0000101903 B C D C D A A B B 0000102396 0000102398 0000102400 0000102397 0000102399 000...

Page 19: ...ion flange with grid 0000102199 Elbow joint KUA 160 0000102409 Rotating flange ball bearing 0000102525 Mounting kit for middle hinge KUA 160 0000102960 Brackets outer tube KUA 2 pcs 0000102989 Rubber...

Page 20: ...www plymovent com 0000111691 011121 B MonoGo...

Reviews: