background image

Unpacking

Thank

 

you

 

for

 

choosing

 ECLISSE INDOOR PL200I

.

 

For

 

your

 

own

 

safety,

 

please

 

read

 

this

 

manual

 

before

 

installing

 

the

 

device.

 

This

 

manual

 

covers

 

the

 

important

 

information

 

on

 

installation

 

and

 

applications.

 

Please

 

install

 

and

 

operate

 

the

 

fixture

 

with

 

following

 

instructions.

 

Meanwhile,

 

please

 

keep

 

this

 

manual

 

well

 

for

 

future

 

needs.

The

 ECLISSE INDOOR 

is

 

made

 

of

 

a

 

new

 

type

 

of

 

high

 

temperature

 

strength

 

of

 

die

 

cast

 

aluminum

 

casing

 

with

 

nice

 

outlook.

 

The

 

fixture

 

is

 

designed

 

and

 

manufactured

 

strictly

 

following

 

CE&RoHS

 

standards,

 

complying

 

with

 

international

 

standard

 

DMX512

 

protocol.

 

It's

 

available

 

independently

 

controlled

 

and

 

linkable

 

with

 

each

 

other

 

for

 

operation.

 

And

 

it

 

is

 

applicable

 

for

 

large-scale

 

live

 

performances,

 

theater,

 

studio,

 

nightclubs

 

and

 

discos.

The

  ECLISSE  INDOOR 

adopts

 

1PCS

 

200W

 

COB

 

LED

 

(available

 

for

 

WW)

 

which

 

features

 

high

 

brightness

 

and

 

stability.

 

Please

 

carefully

 

unpack

 

it

 

when

 

you

 

receive

 

the

 

fixture

 

and

 

check

 

whether

 

it

 

is

 

damaged

 

during

 

the

 

transportation.

 

And

 

please

 

check

 

whether

 

the

 

following

 

items

 

are

 

included

 

inside

 

the

 

box:

1

Plug standard: USA

EURO

UK

ECLISSE INDOOR

1PC

DMX cable

1PC

POWER cable

1PC

POWER OUT

1PC

User Manual

1PC

2

Optional
plug

ECLISSE

 

IN

DOOR

-PL

2

00

-

I

Summary of Contents for ECLISSE INDOOR PL200-I

Page 1: ... ECLISSE Indoor User Instructions PROFILE PL200 I ...

Page 2: ...ke sure the power cord is never crimped or damaged by sharp edges If this would be the case replacement of the cable must be done by an authorized dealer Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal p...

Page 3: ... following CE RoHS standards complying with international standard DMX512 protocol It s available independently controlled and linkable with each other for operation And it is applicable for large scale live performances theater studio nightclubs and discos The ECLISSE INDOOR adopts 1PCS 200W COB LED available for WW which features high brightness and stability Please carefully unpack it when you ...

Page 4: ...using design 4 Metal spot cutting slots 4 kinds of dimming curve Dimming Frequency 500HZ 25000HZ optional Strobe 1 25times sec High quality optical system Glass asphericalr 1 2 DMX channels Control Protocol RDM DMX Auto run and Master Slave control system LCD with touch screen Low noise fan integrated with copper liquid cooling system Working Temperature 10 40 IP20 protection rating Specifications...

Page 5: ... the other side to the male 3 pin XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX 512 connection with DMX terminator 4 ECLISSE INDOOR PL200 I ...

Page 6: ... is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Ω resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below 2 1 3 1 2 3 1 Ground 2 Data 3 Data COMMON DMX DMX 120Ω Pin2 Pin3 EC...

Page 7: ...to the change of temperature Can be Reverse display Multi light working in the same time When using controller to control multi lights to work in strobe the controller just send the channel data The strobe effect will be depend on each light itself And please take attention for the follow situation 1 There will be many situations make the lights are not synchronization in the beginning For example...

Page 8: ...X Mode Axxx A stand for standard channel mode xxx stand for ID address Dxxx D stand for basic channel mode xxx stand for ID address Manual Mode S MC S stand for stand alone mode MC stand for Mixed Color 6 Reverse Display Running Status Vice Menu Button ECLISSE INDOOR PL200 I ...

Page 9: ... Single Mode Choice Menu Operation Vice Menu description White Point Press Key of OK to choose mode Choose color temperature Quick Color Same as before Choose inner setting color Mixed Color Same as before Choose the color and strobe setting Status Menu Description Software Name of software Version Version Temperature Show the temperature of lighting fixture DMX Status With OK Slave mode with sign...

Page 10: ...r Curve Change dimmer curve Standard Incandescent Linear Quick Over Temperature Temperature setting 45 95 Each 5 for increase or decrease Backlight Adjust the display brightness 10 100 Each 5 for increase or decrease Backlight Timeout Screen protect setting No screen protect or black screen from 0 60 second Each 5 for increase or decrease Load Factory Settings Reset ECLISSE INDOOR PL200 I ...

Page 11: ...Standard channel mode 2CH Chann el Data Function Remark 1 0 255 Dimmer 2 0 10 No function 11 25 5 Strobe speed 255 is the fastest Basic channel mode 1CH Channel Data Function 1 0 255 Color 1 8 ECLISSE INDOOR PL200 I ...

Page 12: ... Spectrogram CRI Ra 90 Ra 95 9 ECLISSE INDOOR PL200 I ...

Page 13: ...ere are any damages or severe scratch Make sure the fixture is operated by qualified personnel who knows the fixture before using Keep the original packages if any second shipment is needed Don t try to change the fixtures without any instruction by the manufacturer or the appointed repairing agencies It is not in warranty range if there are any malfunctions from not following the user manual to o...

Page 14: ...el frame Gel holder is clipped into position correctly and cannot come loose If you are not qualified or have any doubts about hanging the led profile spotlight then do NOT hang it Do not clamp the safety cable to the U bracket or clamp That is not a secondary safety point A secondary safety point is any point that will adequately hold the led profile spotlight if the C clamp or half cheesboro fai...

Page 15: ...here The fans keep the LED cool and keep the electronics cool too Without the fan working efficiently and dust free the fixtures will fail and that will be a lot more costly than having someone vacuum the fixtures on a regular basis How often should the fans be cleaned It depends on where the fixtures are in a very dusty atmosphere once a week So check the fans on a regular basis they may not need...

Page 16: ...Voltage LEDs IP Rating T Color Working Position CRI Housing Cooling System DMX Control DMX Channels Weight Dimension Warranty 100V 240V 50 60Hz 200W COB LED IP20 Warm White Any safe working position 90 Die casting aluminum housing design Low noise fan integrated RDM DMX Auto run and Master Slave 1 2CH Manual zoom 25 50 11 4Kgs 820 D 330 W 315 H mm 2 Year https www piu39av com pluslite lighting ...

Reviews: