E-72
When the STATUS Indicator is Lit/Flashes
PC CARD
ACCESS
ENTER
CANCEL
SELECT
+
-
POW
ER
POW
ER
STATU
S
AUTO
SOU
RCE
MEN
U
POWER
STATUS
POWER
STATUS
POWER
STATUS
POWER
STATUS
POWER
STATUS
POWER
STATUS
When an indicator is lit or flashing
The indicators on the projector’s control panel light or flash to no-
tify of problems, as described below.
An indicator is also used to notify you of the currently set power
mode (under normal circumstances). See “Power Cable Connec-
tions and Switching the Power On/Off” on page E-24.
Indicators
Indicator status
What you should do
Lit green
Lit red
Lit amber
Lit red
Lit amber
Flashing red
(lit for 0.5 seconds/off for 0.5 seconds)
Lit amber
Flashing red
(lit for 2 seconds/off for 2 seconds)
Lit amber
Flashing red
(lit for 4 seconds/off for 4 seconds)
Lit amber
Flashing red
(lit for 6 seconds/off for 6 seconds)
It is time to replace the lamp.
Replace with a new lamp cartridge.
The lamp has reached the end of its service life. The power
will no longer turn on.
The projector can be used for 100 hours after the lamp has reached
the end of its service life (when “Remaining Lamp Time” reaches
0%).
Replace with a new lamp cartridge.
The lamp cover is open.
The lamp cover is not properly mounted. Mount it properly.
The temperature is abnormally high.
• The temperature protector has been activated. If the room tem-
perature is high, move the projector to a cool place. If the
projector’s internal temperature is high, check the cooling fan’s
ventilation slots and clean them if they are clogged.
• When the temperature protector is activated, the power turns
off and in some cases will not turn back on immediately. In this
case wait about 1 minute, then try again.
The fan has stopped.
Unplug the power cable and contact a store that sells the U2-
X2000 for repairs.
The lamp will not light.
Wait at least 1 minute, then turn the power back on. If the problem
persists, unplug the power cord and contact a store that sells the
U2-X2000 for repairs.
Should an indicator be in a condition other than normal or flash at a rate other than the aforementioned,
disconnect the power cable and contact your store of purchase.
Thermal Protector
When the internal temperature of the projector becomes abnormally high, the STATUS indicator will flash
red (at a rate of once per second) and the POWER indicator will light red.
The thermal protector is activated and the power of the projector is switched off simultaneously.
Should this occur, proceed with the following actions.
1. Switch off the power and disconnect the power plug from the wall outlet.
2. Check the following matters and take the required measures.
When the projector is being used in a location that has a high ambient temperature, set it up again in
a cool location. Check the outflow and intake holes and clean them if they are obstructed.
3. Wait about 60 minutes until the temperature of the projector drops.
If after having performed the above matters, the problem still has not been solved, please contact your
store of purchase.