Operating Manual MTD-ID
Page 13
Firmware Update
Firmware update of MTD-
ID is done by updating the base unit. You’ll need
an
“
xxx + MTD-
ID” firmware file (xxx = name of the base unit
)
. Please refer to chapter “
Firmware Update
” of
the base unit’s manual for det
ails.
After the firmware update is finished please check power-up messages of both MTD-ID and its
base unit. Both firmware num
bers have to be the same, e.g. “
7.17
”. If they’re different please
repeat the firmware update process, preferable over Ethernet.
Technical Data
Specifications
Operating voltage
5 V DC, ± 5 %
provided by base unit
Power consumption
1.0 W
typical
Environmental character-
istics, operating
Temperature:
+5 °C to +40 °C
Relative humidity:
30 % to 85 %, non-condensing
Environmental character-
istics, non-operating
Temperature:
-10 °C to +60 °C
Relative humidity:
5 % to 95 %, non-condensing
Mechanical
Material
Aluminium, rear plate made of steel
Dimensions
87 (W) x 49 (H) x 161 (D) mm; 3.43 (W) x 1.93 (H) x 6.34 (D) inches
Weight
≈
0.4 kg