background image

1

2

3

4

It may be necessary to turn the shower tray over 

to obtain a through cut on the thicker section of 

the periphery of the tray, depending on the size 

of the blade being used.

Note!  Do not force the rate of cutting and 

only cut at the speed of the cutter to avoid 

separation of the tray layers.

Test fit the shower tray in-situ making any further 

adjustments as necessary to ensure a snug fit.

Note!  It is normal for the tray to appear 

elastic when undertaking a dry test fitting. 

Once you are satisfied, complete the installation 

by following the procedure for solid or suspended 

floors as appropriate.

DO NOT PROCEED IF NOT SATISFIED. 
Note!  If using a Panel Riser Kit and 

Baseboard Accessory pack is used for a 

raised installation, refer to both instuctions 

supplied with the kits.

5

6

3

4

3

4

Note!  Some shower trays have a protective 

film (indicated by a label on the surface) 

which must now be removed. Undertake 

a final inspection of the shower try at this 

stage. DO NOT PROCEED IF NOT SATISFIED. 

We recommend the use of the optional Flexi 

Seal Strip (not supplied). If fitting, follow the 

instructions later in this guide to attach the strip 

to the shower tray at this stage.

Use installation compound adhesive or a suitable 

contact adhesive to cover the full area under 

the shower tray. Apply or trowel to a thickness 

suitable to allow full adhesive support of the 

shower tray. 

Note! Always follow the instructions supplied 

with the adhesive.

Place the shower tray 

A

 in position on the 

floor (ensuring surface is level) and mark the 

perimeter and waste hole on the floor including 

an area outside the perimeter for access to 

connect plumbing (as dictated by the installation 

location) after the shower tray has been installed.
If using a shower tray with a built in tiling 

upstand, allowance must be made for recessing 

the tray into adjacent walls to allow tiling down 

onto the tray surface. 

Form a trench in the floor to hold the waste unit 

and piping. 

Before proceding, dry fit all items in-situ to 

ensure compatibility.

Install the waste unit and piping in the trench in 

accordance with building regulations, protecting 

any exposed threads with masking tape.
If necessary, blank off the trench using 18mm 

ply with waste outlet hole, ensuring that the 

plumbing connections can be made once the 

shower tray is in position.

Installation – 

Solid Floor

Floor Level Installation for Concrete or Other Solid Floors

HB

access area

Summary of Contents for Shower Tray

Page 1: ...Installation Instructions 226DAA 010319SD Shower Tray...

Page 2: ...steam outlet is at a minimum of 350mm from the top of the tray When considering your installation method you should be able to attach or repair your waste or waste outlet in situ Important When handl...

Page 3: ...Parts Supplied Qty 1 A Shower Tray Shape and style of tray may differ from that illustrated...

Page 4: ...d Screwdriver Plywood Board min 18mm thick Masking Tape Cement and Fine Sand Power Drill Drill Bits Hole Cutter Jigsaw 60 Grit Sand Paper Angle Grinder Tools and Materials Required not supplied Note O...

Page 5: ...asure the available area for your intended shower tray Note Ensure the outer tray dimensions remain suitable for your intended enclosure taking into account the reduced are that will result after any...

Page 6: ...e not to damage the visible surface carefully remove any loose material and tidy the cut edge using 60 Grit or similar grade sand paper Test fit the shower tray in situ making any further adjustments...

Page 7: ...ng surface is level and mark the perimeter and waste hole on the floor including an area outside the perimeter for access to connect plumbing as dictated by the installation location after the shower...

Page 8: ...t If fitting a shower enclosure refer to the manufacturers installation instructions Before fitting apply copious amounts of silicone to the edges of the shower tray A against all wall contact points...

Page 9: ...or ensuring surface is level and mark the perimeter on the floor including an area outside the perimeter for access to connect plumbing as dictated by the installation location after the shower tray h...

Page 10: ...that good contact is made with the adhesive Fit the waste unit to the shower tray following the instructions supplied with the unit and protect exposed threads with masking tape Before proceeding dry...

Page 11: ...wer tray and waste pipe The shower tray and all connections MUST now be checked for water tightness flow and adequate drainage over the entire area DO NOT PROCEED IF NOT SATISFIED After all checks and...

Page 12: ...uction at floor level A Consider switching to a Panel Riser Kit or re locating the shower tray Q There is water retaining on the surfaces of the tray A Check that the shower tray is level top rims as...

Page 13: ...pplied Silicone Scissors Small Roller Silicone Sealant Damp Cloth Flexi Seal Strip not supplied with shower tray This product is intended as a flexible tiling upstand and should be fitted to the side...

Page 14: ...attached first with a clean damp cloth allow to dry and then wipe with the IPA wipe supplied in the kit Determine the length of strip required to seal around the shower tray and cut to length with sci...

Page 15: ...d e m e p...

Page 16: ...Product supplied by Plumbworld Customer Service Line 01386 800750...

Page 17: ...Bifold Shower Doors Pivot Shower Doors Hinged Shower Doors Shower Screens From Top Brands Coram Shower Enclosures Mira Shower Enclosures Hydrolux Shower Enclosures Diamond Shower Enclosures With quali...

Reviews: