Four-conductor connection:
Fig. 36 Electric connections diagram (four-
conductor) ecoSTER200 with module A for
regulator ZAB-14.
Two-conductor connection:
The two-conductor connection requires a
5V DC power supply with rated current
of at least 200 mA. ecoSTER200 supply
points: connect GND and +V to external
power
supply.
The power supply is not included with
the
regulator.
Connect lines D+ and D- as shown in the
diagram.
Maximum length of leads to the
additional panel should not exceed 30 m,
whereas their gauge should be at least
0,5 mm
2
.
13.14
Internet connection
ZAB-14 regulator can be connecter with
the Internet via an additional ecoNET300
module.
Detailed
information
are
available on regulator manufacturer’s
website.