Setup Instructions
** With the BaseStation(s) powered off **
1. Select Location of BaseStation/RT Line Extender/RT.
2. Connect Cat5 cable from BaseStation “Transceiver” port to RT Line
Extender “from Base” port.
3. Connect Cat5 cable from RT Line Extender “to Remote” port to RT
“BaseStation link” port on RT.
4. Connect power to RTLEx.
5. Power on BaseStation.
6. Check power and TX lights on RT Line Extender and Power, Sync, and
TX lights on RT to insure system operation.
7. Power on BeltStations and walk-test your system to confirm
performance.
Note:
The RX light on the RT Line Extender and RT
will only be lit when a BeltStation is logged in.
Tips
• Water tight operation is possible for the Cat5 connections on the RT
Line Extender. Please contact TE at http://www.te.com/ and reference
part number 1738607-1 for more information.
• Distances discussed and shown on the diagram are approximate and
have been tested using 100% copper twisted pair Cat5 cable.
• Use of copper clad solid aluminum-core Cat5 cable significantly
reduces distances and/or performance quality of your system.
• Use caution when mounting, especially near foot traffic areas; never
mount directly overhead.
• Use installation template provided for assistance installing securely &
accurately.
• If using ZSync, ensure all BaseStations are powered on and all RT Line
Extenders and RTs are powered on and operational at all times.
• For multiple BaseStations, roaming installations, and detailed
synchronization considerations, contact Pliant for more information.
INSTALLATION TEMPLATE
Line up the RT Line Extender
template and use the crosshairs in
the red dotted circles as reference
points for screw placement.
Note
– This template is fit to scale.
Maximum Distance = 4500 ft
Maximum Distance = 1500 ft
Maximum Distance = 7500 ft