Product Identification 

Product: Slim Pace Clocks 

Model Numbers: MS-0037 through MS-0040 

 

Power Specification 

150W power supply: 100-240V, 50/60Hz, max 2A 

 

 

Information in this manual is subject to change without notice. Pictures and illustrations 

may not accurately depict your version. Please check our website for the most current 

information; our user manuals are available online in the customer service section of our 

website. 

 

FCC Compliance Statement: 

This device complies with Part 15 of the FCC Rules. Operation is subject to the following 

two conditions: (1) this device may not cause harmful interference, and (2) this device 

must accept any interference received, including interference that may cause undesired 

operation. 

 

Contains FCC ID: OUR-XBEEPRO 

Model Xbee-PRO Radio IC 4124A-XBEEPRO

 

 

 

 

 

 

Part Number F972, Rev. 202007 

©2020 Colorado Time Systems.  All rights reserved.

Summary of Contents for CoLorado TIME SYSTEMS Slim Pace Clock

Page 1: ...F972 Rev 202007 Slim Pace Clock User Guide ...

Page 2: ...o change without notice Pictures and illustrations may not accurately depict your version Please check our website for the most current information our user manuals are available online in the customer service section of our website FCC Compliance Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful in...

Page 3: ...ical Installation Operating Instructions 3 Synchronizing clocks Setting time intensity channel PAN and module address Displaying Data on the Clock 6 Segment Timer Tabletop controller Handheld controller generic sport Changing Module Channel and PAN at the control board 7 Standards followed 8 ...

Page 4: ......

Page 5: ...mber must be selected as active in the appropriate menu of the controller see controller manual for more information The default factory settings are channel 4 PAN 0 and module address 1 To change these use the clock s push button described on page 4 You can also set them by changing the switch settings on the clock s control board as described on page 7 Mounting and Power Connection Physical Inst...

Page 6: ...location for power to enter the scoreboard There are knockout locations on the left and right sides of the clock If the better location is the left side where the power cord with AC plug currently is skip to step 6 5 If the right side is the better location carefully remove the small knock out 6 Remove terminal block cover by removing the kepnuts holding it in place with the 5 16 nut driver 7 Use ...

Page 7: ... the screw holes on the cover with the holes on the pace clock and secure to the top and bottom of the pace clock using the 4 supplied screws Operating Instructions Synchronizing clocks To set multiple clocks to the same time they must be set to the same channel and PAN see page 5 Initial Set Up 1 Choose a centrally located clock or scoreboard to designate as Leader 2 Configure Leader and set time...

Page 8: ...mat at 12 the decimal of the fourth digit from the left will light or go out Lit indicates p m and unlit indicates a m When the choice you want is displayed press and hold the button for one second to advance to the next menu Menu 4 Minutes Displays __ 28 Each click increments by one minute When the choice you want is displayed press and hold the button for one second to advance to the next menu T...

Page 9: ...e Advancing past 15 will cycle around to 0 This must be set individually for each clock When the choice you want is displayed press and hold the button for one second to advance to the next menu Menu 9 Set Module Address A and the module address are displayed 1 6 are available Advancing past 6 will cycle around to 0 This must be set individually for each clock When the choice you want is displayed...

Page 10: ...ontroller Follow the instructions on the tabletop controller quick reference sheet to set the tabletop controller to the same channel PAN and module as the clock s and scoreboard s you want to control with it The clock will display game time as sent from the controller You can also turn off the ambient light sensor and set a specific intensity on the clock with the tabletop controller Handheld con...

Page 11: ...ver unscrew the retaining screws and set them in a safe place Carefully lean the digit against the enclosure 4 Set the channel and PAN using the dip switches on the circuit board DIP switch settings Off 0 On 1 Channels Switches 1 4 of S2 0 to 11 are valid PAN ID Switches 5 8 of S2 0 to 15 are valid 0 0 0 0 0 0 0 1 0 4 0 0 0 1 8 0 0 1 1 12 1 0 0 0 1 1 0 1 0 5 1 0 0 1 9 1 0 1 1 13 0 1 0 0 2 0 1 1 0 ...

Page 12: ... CSA C22 2 207 Issue 1989 01 01 Portable and Stationary Electric Signs and Displays General Instruction No 1 1989 10 01 R2008 FCC 47CFR 15B clB Issued 2011 04 21 Title 47 CFR Part 15 Subpart B Unintentional Radiators Class A Verification ICES 003 Issue 2004 01 01 Issue No 4 Interference Causing Equipment Standard Digital Apparatus ...

Page 13: ......

Page 14: ...Customer Service Department www coloradotime com Email support coloradotime com Phone 1 970 667 1000 Toll Free U S and Canada 800 287 0653 Fax 1 970 667 1032 ...

Reviews: