background image

   

www.platon.ru

The phone 

24h 

 

 

Service  

 

Hotlines:

8-800-550-0202 – for calls on the Russian Federation (free)

+7-495-540-0202 – for calls when you are outside the territory of the Russian Federation 

On oard  nit  OBU CSI 1201 version 2016

-B

U

User’s manual                     

 

2

.

0

“GSM” LED

“GNSS” LED

“Beeper” LED

” LED

Balance

Power  LED

“Status” LED

LED indicators signalisation

Please

 

 visually 

 

check

 

 the

 

 functioning

 

 and 

 

correctness

 

 of 

 

the 

 

OBU 

 

operation 

 

prior 

 

to 

 

your 

 

journey, 

 

in 

 

the

 

 course

 

 of 

 

your 

journey 

 

and 

 

after 

 

the 

 

end 

 

of 

 

the 

 

journey 

 

by 

 

monitoring 

 

led 

 

indicators 

 

of 

 

the 

 

OBU.

  

Any

 

 glowing

 

 or

 

 flashing 

 

red 

 

led 

 

indicates 

 

that t

 

he O

 

BU i

 

s f

 

aulty o

 

r h

 

as s

 

ome p

 

roblems.

“Status”   LED   depicts   OBU   operational   mode/submode.   You   may   drive by Federal   highways   only   when   this  
indicator  is  permanently   or   flashing   GREEN.

Flashing 

RED

«Malfunction

» submode.

Permanently RED

«OBU hardware locked

» submode.

Flashing Blinking GREEN

«

ing

Sleep

» submode.   

      

Permanently YELLOW

«Out of Russian Federation 

territory

» submode.

GREEN with RED glimpses.

 

«

»

.

Logically  blocked  submode

Permanently GREEN.

«

Normal

» submode

.

 

   

That   signal   appears   when   OBU leaves the territory of Russian Federation. Please 
unplug  the  OBU. 
Please   do   not   forget to re-connect the OBU to the onboard power supply when 
returning  to  Russia.
If  that  signal  appears  when  you  are  with in  Russian  territory,  please  contact  the  
ETC  Call-Center  and  follow  the  instructions.

You  cannot  drive  by  Federal  highways  because  OBU  is  unusable.  Please  contact  the  
ETC  Call-Center  immediately  and  follow  the  instructions.

OBU goes to “Sleep” mode when OBU is disconnected from external power and not 
moving   for  more  than  5  minutes.
All  other  indicators  are  to  be  OFF  when  OBU  is  in  “Sleeping” mode.  If  that  signal 
persists  even  after  OBU  started  moving,  please  contact  the  ETC Call-Center  and 
follow  the  instructions.

Y

ou  can  drive  by  Federal  highways.

Indicates  OBU's  regular  operation  mode.

You  can  drive  by  Federal  highways,  but  you  have  to  contact  the  ETC  Call-Center  as 
soon  as  possible  and  follow  the  instructions.

You cannot drive by Federal highways because some OBU errors appeared. Please contact  
the  ETC  Call-Center  and  follow  the  instructions.

OFF

OBU in “Transportation” submode, 

discharged or defective.

You  may  transport  the  OBU  to  another  location  with  no  tolling  if  needed.  Only  ETC 
Operator  transfers  OBU  to  “Transportation”  submode  and  only  on  your  request. 
If  the  indicator  will  not  change  after  connecting  OBU  to  the  power  supply,  then  it 
may  be  inoperable.  Please  contact  the  ETC  Call-Center  and  follow  the  instructions.

WARNING:  It  is  prohibited  to  drive  by  Federal  highways  with  discharged  or defective  
OBU  or  without  registered  toll  ticket.

“GSM” LED depicts modem and connection modes. Possibility to drive by Federal highways depends on the OBU 
operational  mode  (“Status”  LED).

Permanently YELLOW

Connection to ETC server failure

.

GREEN with short pauses

OBU is connecting to ETC server

.

Permanently GREEN

 

OBU connected to server

.

Permanently RED

Electromagnetic interference or 

modem malfunction

.

GREEN rare blinking

 

OBU registering in GSM network 

.

GREEN frequent blinking

OBU is trying to connect to ETC 

server.

Alternating GREEN/YELLOW

Data transfer failure

.

OFF

OBU in “Sleeping” submode, 

discharged or defective.

If   such   an   indication   persists   for   more   than   4   hours,   please   contact   the   ETC              
Call-Center  and  follow  the  instructions.

You can drive by Federal highways if “Status” LED is GREEN.

You  can  drive  by  Federal  highways  if  “Status”  LED  is  GREEN.

You  can  drive  by  Federal  highways  if  “Status”  LED  is  GREEN.

You  can  drive  by  Federal  highways  if  “Status”  LED  is  GREEN.

 

You  can  drive  by  Federal  highways  if  “Status”  LED  is  GREEN.
If   such   an   indication   persists   for   more   than   4   hours,   please   contact   the   ETC                 
Call-Center  and  follow  the  instructions.

You  can  drive  by  Federal  high ways  if  “Status”  LED  is  GREEN.
Try  to  identify  the  source  of  the  interference  and  then  remove/disable  it  or  leave  the 
zone   of   radio   “noise”.   If   such   an   indication   persists   for   more   than 4 hours, please 
contact  the  ETC Call-Center  and  follow  the  instructions.

If the indicator will not change after connecting OBU to the power supply, then it may be 
inoperable.  Please  contact  the  ETC  Call-Center  and  follow  the  instructions.

WARNING:  It  is  prohibited  to  drive  by  Federal  highways  with  discharged  or  defective 
OBU  or  without  registered  toll  ticket. 

“GNSS”   LED   depicts   the   mode   of   the   navigation   signal s   receive r   operation.   Possibility   to   drive   by   Federal  
highways  depends  on  the  OBU  operation al  mode  (“Status”  LED).

Permanently RED 

Electromagnetic interference or 

GNSS signals receiver 

malfunction (counteraction 

including)

.

Permanently GREEN

    

GNSS module receives and 

successfully process navigation 

signals

.

Permanently YELLOW

GNSS module got the signals of 

no less than 4 satellites and is 

identifying the coordinates

.

OFF

OBU in “Sleeping” submode, 

discharged or defective.

You can drive by Federal highways if “Status” LED is GREEN.
If LED is YELLOW for more than 1 minute, though you are sure there should be no 
interferences for navigation signals, then please contact the ETC Call-Center and 
follow the instructions.

You  can  drive  by  Federal  highways  if  “Status”  LED  is  GREEN.

You  can  drive  by  no-Federal  highways  only.
Try  to  identify  the  source  of  the  interference  and  then  remove/disable  it  or  simply  
leave   the   zone   of   radio   “noise”.   If   such   an   indication   persists   for   more   than   30  
minutes,  please  contact  the  ETC  Call-Center  and  follow  the  instructions.

If  the  indicator  will  not  change  after  connecting  OBU  to  the  power  supply,  then  it  may  
be  inoperable.  Please  contact  the  ETC  Call-Center  and  follow  the  instructions.
WARNING:  It  is  prohibited  to  drive  by  Federal  highways  with  discharged  or  defective 
OBU  or  without  registered  toll  ticket.

“Beeper” LED  depicts  the  sound  alerts  mode.

Permanently GREEN

       

 

    

S

is ON

ound  alert     

OFF

Sound  alerts  set is minimised 

or  OBU in “Sleeping” submode, 

discharged  or  defective.

See  “Sound alert”  part it ion  for  description  of  signals.
If  needed  you  can  minimise  sound  alerts  set  by  single  short  pressing  the  control key.

If   needed,   you   can   switch   all sound alerts ON   by single short pressing the control key 
(sound  confirmation  will  follow).
WARNING:  It  is  prohibited  to  drive  by  Federal  highways  with  discharged  or  defective 
OBU  or  without  registered  toll  ticket.

Permanently GREEN

   

 

      

The balance is enough for more 
than 100 km trip along Federal. 

Permanently RED

The balance is for less than 100 

km trip along Federal highways.

 

OFF

OBU in “Sleeping” mode, 

discharged or defective.

You  can  drive  by  Federal  highways.
You  can  get  exact  information  about  the  account  balance  via  Personal  Cabinet  or  
via  Call-center

.

You  can  drive  by  Federal  highways.
Please  don't  forget  to  top  up  your  account  in  time.

If  the  indicator  will  not  change  after  connecting  OBU  to  the  power  supply,  then  
it   may be   inoperable.   Please   contact   the   ETC   Call-Center   and   follow   the  
instructions.

WARNING:   It   is   prohibited   to   drive   by   Federal   highways   with   discharged   or  
defective  OBU  or  with out   registered  toll  ticket.

“Balance”  LED  inform s  you  about  account  balance  and  is  for  reference  only.

“Power”  LED  depicts  OBU's  power  supply  mode.

Permanently GREEN

OBU is connected to vehicle 

power circuit via cigarette lighter 

socket

Permanently YELLOW

OBU is powered by a built-in 

battery.

Permanently RED 

Critically low battery.

OFF

OBU in “Sleeping” mode, 

discharged or defective.

You  can  drive  by  Federal  highways  if  “Status”  LED  is  GREEN.
Battery  will  charge  automatically  if  needed.

You  can  still  drive  by  Federal  highways  if  “Status”  LED  is  GREEN.
Please   check   the   connection   to   the   socket   and   fuse   integrity   as   soon   as  
possible.

Please check the connection to the socket and fuse integrity immediately. If OBU 
switches OFF due to full discharge of the battery, please contact the ETC Call-
Center to buy a ticket and follow the instructions.

If the indicator will not change after connecting OBU to the power supply, then it may be 
inoperable.  Please  contact  the  ETC  Call-Center  and  follow  the  instructions.

WARNING:  It  is  prohibited  to  drive  by  Federal  highways  with  discharged  or  defective 
OBU  or  without  registered  toll  ticket.

Reviews: