Platinum ZPL4EL - SS Instructions And Advice For The Use, Installation And Maintenance Download Page 6

6

CONVERSIONS

Disconnect the appliance from the mains supply
prior to any conversions being carried out.

7) CHANGING THE TYPE OF POWER
SUPPLY

Although they leave our factory preset for single-
phase connection, certain appliances may by
converted to the threephase system.
Comply with the following instructions:
a) Remove the hotplate from the top of the cabinet,
overturn it, unscrew screw "Z" and remove under
part  (see fig. 8).

b)  Shift connecting plate on terminal according to
the following chart. This chart is also affixed to the
hob.
c) Insert a supply cable of adequate section (see
chart par. 9) through core hitch on the terminal
board.
d) Connect the phase and earth wires to the relative
terminal board.
e) Fix the supply cable in place using clamp.
f) Refit the hotplate, complying with the above
instructions in reverse.

FIG. 8

FIG. 9

Summary of Contents for ZPL4EL - SS

Page 1: ...he appliance itself The manufacturer shall not be held responsible for any damages to persons or property caused by incorrect installation or use of the appliance The Manufacturer shall not be held re...

Page 2: ...t plate 180 of 2000 W 7 Control knob for electric plate n 1 8 Control knob for electric plate n 2 9 Control knob for electric plate n 3 10 Control knob for electric plate n 4 11 Control knob for elect...

Page 3: ...A red warning light will come on to indicate that the plate has been ignited 2 HOW TO USE THE ELECTRIC PLATES A purely indicative plate regulation chart is given below FIG 1 FIG 2 0 Off 1 1 Weak 2 1...

Page 4: ...mained unused for a long period it should be dried for 30 minutes on switch position n 1 This will eliminate any moisture that may have been absorbed by the insulating material To correctly use the ap...

Page 5: ...between hood and hob fig 5 5 FIXING THE HOB The hob has a special seal which prevents liquids from getting into the cabinet Strictly comply with the following instructions in order to correctly apply...

Page 6: ...Remove the hotplate from the top of the cabinet overturn it unscrew screw Z and remove under part see fig 8 b Shift connecting plate on terminal according to the following chart This chart is also aff...

Page 7: ...ppliance repeat the inverse process 9 TECHNICAL CHARACTERISTICS OF THE ELECTRICAL COMPONENTS To facilitate the job of the installer we present a scheme with the characteristics of the components POWER...

Page 8: ...h protector VOLTAGE 230 240 V FREQUENCY 50 60 Hz TOT RATING 5500 W MODEL WITH 3 NORMAL PLATES with protector 1 THERMOSTAT PLATE 8 TECHNICAL DATA This appliance is marked according to the European dire...

Reviews: