9
6. Turn the steam knob to
position and make steam for 2min, then turn the
steam knob to
OFF
RELEASE
position to stop the unit immediately, make the
descalers deposit in the unit at least 15 minutes.
7. Restart the unit and repeat the steps of 4-5 at least 3 times.
8. Then turning the steam knob to
position to brew until no descaler is
left.
9. Then brewing coffee (no coffee powder) with tap water in the MAX level,
repeat the steps of 4-5 for 3 times (it is not necessary to wait for 15 minutes
in step of 5), then brewing until no water is left in the tank.
10. Repeat the step of 8 at least 3 times to make sure the piping is cleanly.
TROUBLE SHOOTING
Symptom
Cause
Corrections
Carafe leakage water
or water leaks out
from lid of carafe
The carafe is not located
properly
Let centreline of carafe
aligns with leakage
opening of brew basket
well.
The level of water in the
tank exceeds the scale of
MAX.
The water level in the tank
should be within the scale
of MIN and MAX.
The metal parts in the
tank have rust.
The descaler is not
recommended type. It
may corrode the metal
parts in the tank.
Use the descaler
recommended by
manufacturer.
ENGLISH