UGP-712
15
Drive
Arm
Limit Disc
A. Loosen the screws on the Limit Switch Cams.
B. Remount the articulated arm, making sure
the cam wheel pin is engaged with the
clutch.
C. Move the gate manually to the closed position.
D. Move the Limit Switch Cams on the Cam
Wheel to actuate each limit switch.
E. Slightly tighten the screw on the Limit
Switch Cam.
F. Move the gate manually to the open
position. Repeat steps a, b and c for the
other cam.
G. Run the unit 2 full cycles without
interruption (from limit to limit) to
execute a “Learn Cycle.”
Gate Opens to Right
Left Limit Switch
Open limit
Right Limit Switch
Close limit
Gate Opens to Left
Left Limit Switch
Close limit
Right Limit Switch
Open limit
Limit Switch Cam
Limit Disc
Limit Switch Cam
Right
Limit
Switch
Left
Limit
Switch
Right
Limit
Switch
Left
Limit
Switch
Drive
Arm
A. Loosen the screws on the Limit Switch Cams.
B. Lock the Manual Release Mechanism. That means the gate attachment Bracket-E is locked
with the gate.
C. Using the close & stop buttons on the control board to move the gate to the close position.
D. Move the Limit Switch Cams on the Cam Wheel to actuate each limit switch.
E. Slightly tighten the screw on the Limit Switch Cam.
F. Using open & stop buttons on the control board to move the gate to open position. Repeat
step D and E to setup open limit cam.
G. Run the unit 2 full cycles without interruption (from limit to limit) to execute a “Learn Cycle.”
GATE OPENS TO RIGHT
Left Limit Switch
Open limit
Right Limit Switch
Close limit
GATE OPENS TO LEFT
Left Limit Switch
Open limit
Right Limit Switch
Close limit
Step 15
STEP 16.
Adjust the mechanical Positive stop B & C correctly.
STEP 17.
Verify the limit switches are set correctly. Reset the unit. Then press the open button to open the
gate(s) all the ways. Then Press the close button to close the gate all the way. Repeat this process for three
times. Verify the gate work correctly according to the Timer setting, Gate SNS setting, and Gate SYNC setting .
STEP 19.
After you have verified the gate(s) working properly, then you can put the top cover in place and
secure it with two screws.
Mounting Instructions
STEP 15.
Adjusting the limit switches in the chassis to set the open limit and close limit.
www.BrushlessGateOpeners.com | (800) 878-7829 | [email protected]