23
Dingo 2020N User Guide
Specifications
Nominal system voltages
12,24,32,36,48 V
Maximum voltage BAT+ to BAT-
100
V
Maximum short term voltage BAT+ to BAT-
(2 minutes)
120
V
Maximum voltage SOL+ to BAT- (for a 48V system)
100
V
Maximum voltage LOAD+ to BAT+
70
V
Maximum voltage between the ‘G’ relay terminals
90
V
Maximum voltage B+ sense to BAT+
+/- 30
V
Maximum continuous charge current (SOL+)
20
A
Maximum continuous load current (LOAD+)
20
A
Maximum short term load current (5 minutes)
30
A
Maximum ‘G’ relay contact current
300
mA
Battery temperature sensor operating range
-20 to +70
o
C
Maximum storage temperature
70
o
C
Supply current (device only, battery at 12V)
<13
mA
Supply current (device only, battery at 60V)
<16
mA
Maximum supply current (with accessories)
27
mA
Meter accuracy
<+/-2% +/- 1 digit
Maximum wire entry size (large terminals)
16mm
2
(6 AWG)
Wire size, Green terminal block 0.2-1.3mm
2
(26 -16 AWG)