PlasmaPart PlasmaOne 50A Operation & Safety Manual Download Page 3

Important Safety Information 

The following information is extremely important and must be 
observed, this section is in addition to specific hazard warnings that 
are mentioned throughout the manual where appropriate

 

The operation and routine maintenance of plasma cutting equipment can be 
extremely dangerous and hazardous to your health and wellbeing

The plasma cutting process produces strong electric and magnetic emissions which 

may cause improper or non-function of cardiac pacemakers, and other electrical 
health equipment & devices. Consult your doctor if you are in any doubt before 
using or being in close proximity of a working plasma cutter. 

Electric Shock 

Electric shock can injure or kill you, the plasma arc process requires high voltages at 

high currents to create the high temperature plasma beam. This high voltage and 
high current can cause serious injury or death to you or others in the workplace. 

 

 

Never touch any components or parts that are electrically live or hot 

 

Never change consumables or parts of the torch when the machine is turned on 

 

Always ensure parts and consumables are replaced when they are worn or damaged  

 

Do not operate the machine in damp or wet conditions  

 

Ensure the machine is used in conjunction with an appropriate RCD 

 

Insulate yourself from the work piece and any other parts of the circuit using 
appropriate safety equipment such as gloves  

 

Read and follow all instructions in the operation manual, if you are unsure about any 
of them please contact us 

 

The work piece should be earthed either direct to ground or to the earth terminal on 
the rear of the machine 

Fire and Explosion  

When plasma cutting there is a risk that sparks, slag, plasma arc, conducted heat or 
a combination of these could cause flammable or potentially explosive materials to 

ignite or detonate. 

 

Ensure that all combustible materials are removed from the affected area 

 

Protect yourself and flammable materials that cannot be moved 

 

Never cut a container or vessel that has held flammable or volatile substances 

Summary of Contents for PlasmaOne 50A

Page 1: ...Operation Safety manual 50A PlasmaOne 50A PlasmaOne 50Amps DC Single Phase 240V Inverter plasma cutter...

Page 2: ...in the correct and safe use of your PlasmaPart product please read and fully understand it before use Your understanding of the product is key to your safety plasma cutting is hazardous by taking the...

Page 3: ...e Never touch any components or parts that are electrically live or hot Never change consumables or parts of the torch when the machine is turned on Always ensure parts and consumables are replaced wh...

Page 4: ...oduced during plasma cutting can be hazardous to health and should not be inhaled Certain materials produce more toxic fumes and great care should be taken when cutting any material made from or conta...

Page 5: ...level to ensure it is below recommended levels of exposure Plasma Arc Ultraviolet Radiation Plasma arc radiation can burn your eyes and skin without adequate protection your eyes and skin are at risk...

Page 6: ...bed in this manual conforms to all applicable aspects and regulations of the EMC directive and to the national legislation for the enforcement of this directive PlasmaPart machines are the result of e...

Page 7: ...from you to us in the event of a warranty claim you may be charged some of the repair costs if the machine has not been packaged adequately The warranty explicitly excludes Consumables electrodes nozz...

Page 8: ...er requirement at 50A 6 0 KVA Max Rated input current at 50A 30 A Max No load voltage 230 V Output current range 20 50 A Output voltage range 88 96 V Duty cycle 50 Amps Output 60 Efficiency 85 Cut Wid...

Page 9: ...y ionised gas stream This is created by passing air at high velocity whilst spinning through a carefully formed arc the arc is formed between the hafnium tip of the electrode and the inner surface of...

Page 10: ...sing your machine with an appropriately sized RCD or residual current device Compressed air supply Your new PlasmaPart system is equipped with a PCL type quick air connection Once you have attached yo...

Page 11: ...l this adjusts the output pressure of the compressed air supply to the PlasmaPart system In order to adjust this lift the knob slightly and you should hear a slight click as the knob engages you can n...

Page 12: ...n rapidly cause very expensive damage to the torch in some cases incorrect assembly can be dangerous and may also affect your warranty Full torch assembly information can be found in your torch manual...

Page 13: ...e when cutting as the cut quality will decrease as the gap increases above the material Try to ensure the material being cut is as clean as possible before cutting this will improve the cut quality an...

Page 14: ...d on and has correct air supply Check work piece connection Disassemble torch consumables and check for worn electrode loose electrode this needs to be nipped up but not overtightened missing or damag...

Page 15: ...e years of operation If you need to get in touch for advice to purchase spares for warranty support service or for any other reason you can contact us here PlasmaPart Limited Unit 1 Debdale Lane Keywo...