7
4.
MONTAGE
WARNING
! All elements above the fireplace need to be made of non-flammable materials.
•
The dimensions of the housing are to be chosen according to the technical drawings and a ventilation grid or
slot
–
with ventilation area min 150 cm2 for fireplaces length up to 1500mm and 300cm2 for fireplaces length
above the 1500mm
–
needs to be placed near the base of the unit, minimally 110 mm below the burner surface.
Please note if not possible there has to be additional drainage installed to lead out water from the cavity.
•
If a hood is placed above the burner it needs to be made of non-flammable materials and a minimum distance
of 60 cm from the surface of the burner needs to be observed.
WARNING!
If the housing is devoid of a diagonal hood above the burner one needs to remember that all surfaces
inside the housing exposed to contact with hot air need to be made of non-flammable materials.
•
It is not permitted to use a device which is not housed in some way.
Non-flammable
materials
Ventilation grate or slot with ventilation area of
minimum 150 cm
2
for fireplaces length up to
1500mm and 300cm
2
for fireplaces length
above the 1500mm
The dimensions and shape of the ventilation grid may be designed according to
client specifications however both the minimum ventilation area of (150 cm
2
for fireplaces length up to 1500mm and 300cm
2
for fireplaces length above the
1500mm) as well as minimum distance from the edge of the housing of 110
minimum need to be observed.
In accordance with fire safety measures
there should be no flammable objects in
direct contact with the device nor within a
1 metre radius from the fire. Additionally,
Planika doesn't recommend placing heat-
sensitive objects above the fireplace as it
may shorten their lifetime. Planika will not
be responsible for any damage caused by
high temperature affecting objects
installed above the fire.