background image

www.planikafires.com   

 

   

 

 

 

i0776#01    

30.04.2014 

 4 

-

 

total time of the product operation 

-

 

website version 

 

Thanks to 

MANAGER

 function it is possible to control unlimited number of configured bio fireplaces. 

 

If  Wi-Fi  network  has  access  to  the  Internet,  it  is  possible  to  enter 

www.planikafires.com

  or 

www.fireline.planikafires.com/fla

 

WARNING! 

To control the bio fireplace, it needs to be installed according to the Installation Manual. The user has 
to be familiar with the User’s Manual. Only after the configuration it is permitted to turn on the product 
for the first time. 

 

 

 

 

 

Summary of Contents for FKE-0683

Page 1: ...enu point 1 Choose the bio fireplace which is to be controlled It will be also possible to check the serial number program version website version and total operating time FLA 3 communicates with the exterior appliances by means of Wi Fi Make sure that Wi Fi network you have is of 802 11 b g n standard and it operates the encryption of WPA WPA2 PSK If your Wi Fi network does not fulfill the above ...

Page 2: ...ule at all It is normal during the initialization of the product If it does not disappear after several minutes after turning on the bio fireplace begin to format USB flash drive again 0 0 0 2 No connection with the network wrong data IP is busy no network Follow the procedure of giving the network parameters once more install USB flash drive again 0 0 0 3 Text mode jumper was not downloaded Follo...

Page 3: ...network The operation of bio fireplace via website was tested with the following browsers Windows Opera Firefox Chrome IE min 11 Android Firefox Chrome Opera Browser Opera Classic Safari Apple Safari Chrome In the address bar enter the saved IP address and download the webpage The display will appear on the appliance Due to SETTINGS function it is possible to determine Serial number Display and mi...

Page 4: ...d bio fireplaces If Wi Fi network has access to the Internet it is possible to enter www planikafires com or www fireline planikafires com fla WARNING To control the bio fireplace it needs to be installed according to the Installation Manual The user has to be familiar with the User s Manual Only after the configuration it is permitted to turn on the product for the first time ...

Page 5: ... message WORKING lack of fuel message NO FUEL waiting for an occurrence message WAITING or COOLING THE DEVICE ERROR XX The description of Smart Home System ports Description of electrical connectors GND COM DC V START 12 DC V input initializing the bio fireplace signal as an impulse lasting 100ms up to 1s STOP 12 DC V input turning off the bio fireplace signal as an impulse lasting 100ms up to 1s ...

Page 6: ...er installed on the module s port There is possibility to control a few bio fireplaces simultaneously In order to do so it is essential to divide the signal into several ones one per each product Scheme Description Input voltage port 12V 24V of the direct current OUTPUT voltage port 12V 24V of the direct current depending on the mode of the bio fireplace Chart with the signals that may occur depen...

Page 7: ...eases flame size by one level A single impulse directed to DOWN port decreases flame size by one level Electrical connector READY indicates that the bio fireplace is ready to start Electrical connector WORKING indicates that the bio fireplace is working Disappearance of the signal is equal to turning off the product or lack of fuel Electrical connector FUEL indicates lack of fuel Electrical connec...

Reviews: